37
3 - Description
Menus
Full Menu Structure
The below menu structure is correct for SW A.2.2.53 - later versions can differ from this.
÷
NOTE! Blank fields are menus without name or description.
Menu Number Menu Name Help Text in Display
1 Daily settings Most used settings e.g. desired rate, tank contents and register number
1. 1 Volume rate Use arrow keys or numeric keys to set the desired volume rate
1. 2 Reserved Reserved Reserved Reserved
1. 3 Select register Use register 1 to 99 for job. Scroll to register, then press Enter to show data
1. 3. 1 Show register spray data 1 Use register 1 to 99 for job. Scroll to register, then press Enter to show data
1. 3. 1. 1 Show register spray data 1 Press C for 5 sec to reset register. Enter to see screen 2, ESC to leave
1. 3. 1. 1. 1 Start date
1. 3. 1. 1. 2 Start time
1. 3. 1. 1. 3 End date
1. 3. 1. 1. 4 End time
1. 3. 1. 2 Show register spray data 2 Press C for 5 sec to reset register, Enter to see screen 1, ESC to leave
1. 3. 1. 2. 1 Vol. sprayed
1. 3. 1. 2. 2 Area spray
1. 3. 1. 2. 3 Average spray speed
1. 3. 1. 2. 4 Maximum spray speed
1. 3. 1. 2. 5 Travelled spray dist
1. 3. 1. 2. 6 Time used spraying
1. 3. 1. 2. 7 Work rate
1. 3. 1. 2. 8 Average volume rate
1. 3. 2 Select register Use register 1 to 99 for job. Scroll to register, then press Enter to show data
1. 3. 3 Total register Shows register number 0 which is a total of all registers
1. 3. 99. 1 Show register spray data 1 Press C for 5 sec to reset register, Enter to see screen 2, ESC to leave
1. 3. 99. 2 Show register spray data 2 Press C for 5 sec to reset register, Enter to see screen 1, ESC to leave
1. 4 Volume rate: Present high Rate selected with1 press on the arrow up-key
1. 5 Volume rate: Present low Rate selected with1 press on the arrow down-key
2 Setup Customization of display, automatic functions, clock, alarms, registers, etc
2. 1 Display readout Customizes the 4 small display readouts
2. 1. 1 Show upper middle
2. 1. 1. 01 Prog volume rate litre/ha Shows Programmed volume rate Application rate litre per hectare
2. 1. 1. 02 Boom flow Boom flow per minute sprayed out through the boom
2. 1. 1. 03 Time Actual time
2. 1. 1. 04 Work rate ha/hour Rate shown in hectare per hour or acre per hour
2. 1. 1. 05 Actual volume rate litre/ha Actual rate in litre per hectare or gallon per acre
2. 1. 1. 06 Tank contents Main tank contents
2. 1. 1. 07 Speed Driving speed
2. 1. 1. 08 Volume sprayed Readouts for Volume sprayed in currently active register
2. 1. 1. 09 Area sprayed Readouts for Area sprayed in currently active register
2. 1. 1. 10 Active boom size Active boom size including end nozzle
2. 1. 1. 11 Pressure Displays spray pressure if sensor is fitted
2. 1. 1. 12 Fan speed Displays Twin fan speed if sensor is fitted
2. 1. 1. 13 Regulation valve angle
2. 1. 1. 14 Pendulum lock status Displays reading of pendulum lock sensor if fitted
2. 1. 1. 15 Pendulum unlock status Displays reading of pendulum unlock sensor if fitted
2. 1. 1. 16 Dynamic centre position Displays Dynamic centre position sensor if fitted
2. 1. 1. 17 Spray pump rev Displays revolutions if sensor is fitted

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hardi SMARTCOM ISOBUS UT SW A.2.2 Series and is the answer not in the manual?

Hardi SMARTCOM ISOBUS UT SW A.2.2 Series Specifications

General IconGeneral
BrandHardi
ModelSMARTCOM ISOBUS UT SW A.2.2 Series
CategoryFarm Equipment
LanguageEnglish

Related product manuals