Menu 3.4.2 Simulated speed value
The “Simulated speed value menu is used in 2 situations:
In addition, when the spraying speed drops below the lowest
speed where a spray job can begin when starting at the headland,
then the speed will be simulated to maintain normal spray
pressure until the normal spraying speed is maintained.
When the nozzles are open, then the application rate is calculated
based on the measured flow, boom width and simulated speed.
This is desired, because it works as a limp home state when the
driving speed sensor is defect.
Default value: 7.2 km/h
μ
ATTENTION! Use this menu when a spray job has to be
finished before fixing the defect sensor.
μ
ATTENTION! The recommended setting is 75-90% of the
normal spraying speed.
When stand still or driving very
slow while priming the boom.
This feature allows the operator to stand still or drive slow and automatically get
normal spray pressure to prime the boom.
If the speed sensor is defect. In this case the computer will assume that the sprayer is traveling with the speed
typed in this menu.
The operator should keep the tractor constantly at this speed to maintain a good
regulation with the ability to handle changes in the application rate and changes
in open or closed sections.
The speed entered should be appropriate also for headlands. If the speed is
reduced at headlands, resulting that the application rate will be higher than set
value. I.e., if the operator selects an application rate of 100 litre/ha and a speed of 8
km/h and then reduces the speed to 6 km/h at headlands, then the actual
application rate will increase to 133 litre/ha.
Simulated speed value
km/h
Type in speed for priming at
stand still and when both flow
and pressure are defect

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hardi SMARTCOM ISOBUS UT SW A.2.2 Series and is the answer not in the manual?

Hardi SMARTCOM ISOBUS UT SW A.2.2 Series Specifications

General IconGeneral
BrandHardi
ModelSMARTCOM ISOBUS UT SW A.2.2 Series
CategoryFarm Equipment
LanguageEnglish

Related product manuals