Select the position of temperature information showed on the live view.
Near Target
Display the information beside the temperature measurement rule.
Top Left
Display the information on the top left of screen.
Add Original Data on Capture
Check to add data on alarm triggered capture of thermal channel.
Add Original Data on Stream
Add and save original raw data to stream. The function requires higher network
bandwidth.
Picture Quality
Set picture quality as high, medium, or low.
Data Refresh Interval
It means the refresh interval of original data.
Display Pixel-to-Pixel Thermometry Data on Stream
Add and save real-time pixel-to-pixel thermometry data to stream. The function
requires higher network bandwidth.
The function varies according to different camera models.
Pixel-to-Pixel Thermometry Data Refresh Interval
It means the refresh interval of thermometry data added to the stream.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin
(K).
Temperature Range
Select the temperature measurement range. The device can adjust the temperature
range automatically if you select Auto.
Atmospheric Temperature
Set the atmospheric temperature.
Atmospheric Humidity
Set the atmospheric humidity.
Atmospheric Transmissivity
Set the atmospheric transmissivity from 0 to 1.
Distance Mode
Select the distance mode for temperature measurement.
Self-Adaption
Thermal & Optical Bi-spectrum Network Camera User Manual
54