User Manual of Network Video Recorder
85
11.2.2 Manually Rebuilding Array
Purpose:
If the hot spare disk has not been configured, you can rebuild the array manually to restore the array when the
array is in the HDD Loss status.
Steps:
1. Enter the Array Settings interface. The disk 5 is lost.
Device Management> Remote Management> HDD >Array Configuration >Array
Figure 11. 15 Array Settings Interface
2. Enter the Logical Disk interface to check the status of the logical disk. The logical disk is in Degrade status.
Figure 11. 16 Logical Disk Interface
3. Click Array tab to back to the Array Settings interface and click Recreate button to configure the array
rebuilding.
Note: At least one physical disk should be available for rebuilding the array.
Figure 11. 17 Rebuild Array Interface
4. Select the available physical disk and click Yes to confirm to rebuild the array.
You can enter the Array Settings interface and Logical Disk interface to view the rebuilding status.
5. After rebuilding, the status of array and logical disk will restore to Normal.
Note: It is recommended to set the hot spare disk for automatically rebuilding the array.