MAINTENANCE
7-51
5
Clean Fuel Solenoid Pump Strainer
--- every 500 hours
Cleaning
When strainer (3) is disassembled, be sure to replace gasket
(2) and (4). Install cover (1) and the magnet only after suffi-
ciently cleaning them. After being assembled, closely check
the air-tightness of strainer (3).
Disassembling/Assembling
To remove cover (1), loosen with a spanner. After cover (1)
is removed, gasket (2), strainer (3), and gasket (4) are easily
removed in order. Wash removed strainer (3) with light oil.
Install strainer (3) in the reverse order of disassembling. At
that time, install gasket (2) into cover (1) first. Then, securely
tighten cover (1) to pump (5) using a spanner.
NOTE: Wrench size: 17 mm
M1GR-07-004
M1U1-07-006
1 2 3 4 5
Magnet
36 mm
28 mm
2.7 mm 1 mm
3
2
4
ø41
ø24
ø51
ø18
ø40
ZX330-3 Class
Fuel Solenoid Pump
M1U1-07-074
Fuel Solenoid
Pump
Fuel Solenoid
Pump
ZX200-3, 270-3 Class
M1U1-07-071
ZX180-3 Class
M1U1-07-098
M1U1-07-103
ZX120-3 Class
Fuel Solenoid Pump

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi ZAXIS 180-3 class and is the answer not in the manual?

Hitachi ZAXIS 180-3 class Specifications

General IconGeneral
BrandHitachi
ModelZAXIS 180-3 class
CategoryExcavators
LanguageEnglish

Related product manuals