88 Chapter 12 Certification and Approvals
Searchline Excel™ Plus / Searchline Excel™ Edge – Technical Manual
UL 600797, Standard for Explosive Atmospheres - Part 7: Equipment Protection by Increased Safety ‘E’, Edition 5
(2017)
UL 6007928, Explosive Atmospheres - Part 28: Protection of Equipment and Transmission Systems Using Optical
Radiation, Edition 2 (2020)
UL 6007931, Explosive Atmospheres - Part 31: Equipment Dust Ignition Protection by Enclosure “t”, Edition 2 (2020)
UL 610101, Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 1:
General Requirements, Edition 3rd (2019)
UL 1203, ExplosionProof and DustIgnitionProof Electrical Equipment for Use in Hazardous (Classified) Locations,
Edition 5 (2020)
UL 913, Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, and III, Division 1, Hazardous
(Classified) Locations, Edition 8 (2019)
12.4INMETRO Certification
Not applicable at the moment.
12.5Labelling
ATEX / IECEx certification label
Searchline Excel Plus – Receiver Searchline Excel Edge – Receiver
2017E0050
THISDOCUMENTHASBEENGENERATEDUSINGINDESIGN
ANDMUSTONLYBEUPDATEDBYINDESIGN
Cl. I, Div.1, Gr. B,C,D, T4 (Ta 55°C to +75°C)
Cl. II, Div.1, Gr. E,F,G, T4 (Ta 55°C to +55°C)
Cl. III
Cl. I, Zn. 1 AEx db ia op is IIC T4 Gb (Ta 55°C to +75°C)
Cl. I, Zn. 1 AEx db eb ia op is IIC T4 Gb (Ta 55°C to +75°C)
Zn. 21 AEx ia op is tb IIIC T100°C Db (Ta 55°C to +55°C)
Ex db ia op is IIC T4 Gb X (Ta 55°C to +75°C)
Ex db eb ia op is IIC T4 Gb X (Ta 55°C to +75°C)
Ex ia op is tb IIIC T100°C Db X (Ta 55°C to +55°C)
Ø=72 mm
NOTES:
1.CERTIFICATIONLABELMATERIAL:STAINLESSSTEELSHEETMETALTOUNS S31603,THICKNESS0.2/0.6
mm.
2.INTERNALWIRINGLABELMATERIAL:THERMALTRANSFERPOLYESTERLABEL
3.UNIQUESERIALNO:CONTAINSYEARDATAFORMONTHANDYEAROFMANUFACTURE.
4.OTHERMARKINGANDAGENCYDETAILSFORADDITIONALCERTIFICATIONSMAYBEADDED,NOTRATIFIEDBYUL.
North America (USA and Canada)ATEX / IECEx / INMETRO
Part No. XXXXXXXXX
FINISH
N/A
MATERIAL
SEENOTE1AND2
SCALE
1:1
05 04 03 02 01 ISSUE
31/05/21 16/02/21 11/02/21 09/12/20 15/04/20
DATE
CHANGE
KSM KSM KSM KSM KSM
ACTIONEDBY
DRAWNK.SMRCEK DATE15-Apr-20
TITLE
ULCERTDRG-SEARCHLINEEXCELPLUSRx
ATEX/IECExANDNORTHAMERICAN
CERTLABELDETAILS
2017E0050
SHT.1
OF1
Mod State: 1 2 3 4 5 6 7 8 9 10
Part No. XXXXXXXXX
Supply Voltage: 24V dc (18 to 32V max), Overvoltage Category II
Pmax: 15W (Ta -30°C), Pmax: 10W (Ta -30°C)
Contains Transmitter Module FCC ID HD5SFPMB
Contains Transmitter Module IC 1693BSFPMB
Contains Intrinsic Safety Circuits Ex ia: Um = 250V RMS
Intrinsically Safe - À Sécurité Intrinsèque
Patent: www.hsmpats.com
LEAKDETECTION
EQUIPMENT FOR USE IN
HAZARDOUS LOCATIONS
Serial No.
Serial No.
©2020LIFESAFETYDISTRIBUTION
GmbH.
ALLRIGHTSRESERVED.
THISDOCUMENTCONTAINSPROPRIETARY
INFORMATIONOFLIFESAFETY
DISTRIBUTIONGmbHANDITSAFFILIATED
COMPANIESANDISPROTECTEDBY
COPYRIGHTANDOTHERINTERNATIONAL
LAWS.REPRODUCTIONORIMPROPER
USEWITHOUTSPECIFICAUTHORIZATION
OFLIFESAFETYDISTRIBUTIONGmbHIS
STRICTLYFORBIDDEN.
TOLERANCESTOBEASSPECIFIED
BELOWUNLESSOTHERWISESTATED.
DIMS.2DP±0.1mm
1DP±0.25mm
NONE±0.4mm
ANGULAR±1/2°
HOLESØ0to8
+0.08
-0.0
Ø8to14
+0.1
-0.0
Ø14to25
+0.12
-0.0
UNLESSOTHERWISESTATED:
ALLDIMENSIONSINMILLIMETRESTO
APPLYAFTERPLATING.
ALLTHREADSTOBEBS3643.
REMOVEALLBURRSANDSHARPEDGES.

SURFACETEXTUREVALUESAREINm
RaANDTOBS 1134.
THISDRAWINGISTOBS8888.
DNV 21.0105 X
DEMKO 20 ATEX 2281X / UL21UKEX2047X /
IECEx UL 20.0009X
(Ex d install) Ex db ia op is IIC T4 Gb (Ta 55°C to +75°C) or
(Ex de install) Ex db eb ia op is IIC T4 Gb (Ta 55°C to +75°C)
Ex ia op is tb IIIC T100°C Db (Ta 55°C to +75°C)
IP66/67
Supply Voltage: 24V dc (18 to 32V max), Overvoltage Category II
Pmax: 15W (Ta -30°C), Pmax: 10W (Ta -30°C)
Contains Intrinsic Safety Circuits Ex ia: Um = 250V RMS
Patent: www.hsmpats.com
THISITEMFORMSPARTOFACERTIFIEDPRODUCT.NO
MODIFICATIONPERMITTEDWITHOUTREFERENCETOCERTIFYING
AUTHORITY
Mod State: 1 2 3 4 5 6 7 8 9 10
A3
GYJ18.1482X
IP66/67,
Type 4/4X
APPROVED
FOR PERFORMANCE ONLY
60079-29-4
II 2 GD
2813
0518
H
o
n
e
y
w
e
ll
A
n
a
ly
t
ic
s
L
td
.
,
P
o
o
le
,
D
o
r
s
e
t,
B
H
1
7
0
R
Z
M
a
d
e
i
n
U
K
H
o
n
e
y
w
e
ll
A
n
a
ly
t
ic
s
L
td
.
,
P
o
o
le
,
D
o
r
s
e
t,
B
H
1
7
0
R
Z
M
a
d
e
i
n
U
K
S
e
a
r
c
h
l
i
n
e
E
x
c
e
l
P
l
u
s
-
O
p
e
n
P
a
t
h
F
l
a
m
m
a
b
l
e
G
a
s
L
e
a
k
D
e
t
e
c
t
o
r
-
R
e
c
e
i
v
e
r
S
e
a
r
c
h
l
i
n
e
E
x
c
e
l
P
l
u
s
-
O
p
e
n
P
a
t
h
F
l
a
m
m
a
b
l
e
G
a
s
L
e
a
k
D
e
t
e
c
t
o
r
-
R
e
c
e
i
v
e
r
Lire et comprendre le manuel avant d’installer, d’utiliser ou de réparer
l’équipement. La substitution des composants peut nuire à la sécurité
intrinsèque. Ne pas ouvrir l’équipement dans des atmosphères
contenant des explosifs. Scellez le conduit à moins de 50
mm. Risque potentiel de charge électrostatique,
voir les instructions.
Read and understand manual before installation, operation or servicing. Substitution of
components may impair intrinsic safety. Do not open when an explosive atmosphere is
present. Potential electrostatic charging hazard, see instructions.
Não abra quando uma atmosfera explosiva estiver presente
Risco potencial de carga eletrostática
ver instruções.
WARNING / AVERTISSEMENT
WARNING / ATENÇÃO
Read and understand manual before installation, operating or servicing. Substitution of
components may impair intrinsic safety. Do not open when an explosive atmosphere is present.
Seal conduit within 50 mm. Potential electrostatic charging hazard, see manual.
Explosion protection
mark and equipment
group and category
CE mark
Conforms to all
applicable
European directives
Warning
Certified
ambient
temperature
Certification number
Serial number
Part number
Modification state
Certification code as
IEC / EN600790:
IEC / EN600791: and
IEC / EN 60079 - 28
2017E0052
THISDOCUMENTHASBEENGENERATEDUSINGINDESIGN
ANDMUSTONLYBEUPDATEDBYINDESIGN
Cl. I, Div.1, Gr. B,C,D, T4 (Ta 55°C to +75°C)
Cl. II, Div.1, Gr. E,F,G, T4 (Ta 55°C to +55°C)
Cl. III
Cl. I, Zn. 1 AEx db ia op is IIC T4 Gb (Ta 55°C to +75°C)
Cl. I, Zn. 1 AEx db eb ia op is IIC T4 Gb (Ta 55°C to +75°C)
Zn. 21 AEx ia op is tb IIIC T100°C Db (Ta 55°C to +55°C)
Ex db ia op is IIC T4 Gb X (Ta 55°C to +75°C)
Ex db eb ia op is IIC T4 Gb X (Ta 55°C to +75°C)
Ex ia op is tb IIIC T100°C Db X (Ta 55°C to +55°C)
Ø=72 mm
NOTES:
1.CERTIFICATIONLABELMATERIAL:STAINLESSSTEELSHEETMETALTOUNS S31603,THICKNESS0.2/0.6mm.
2.INTERNALWIRINGLABELMATERIAL:THERMALTRANSFERPOLYESTERLABEL
3.UNIQUESERIALNO:CONTAINSYEARDATAFORMONTHANDYEAROFMANUFACTURE.
4.OTHERMARKINGANDAGENCYDETAILSFORADDITIONALCERTIFICATIONSMAYBEADDED,NOTRATIFIEDBYUL.
North America (USA and Canada)ATEX / IECEx / INMETRO
Part No. XXXXXXXXX
FINISH
N/A
MATERIAL
SEENOTE1AND2
SCALE
1:1
04 03 02 01 ISSUE
02/06/21 11/02/21 09/12/20 15/04/20
DATE
CHANGE
KSM KSM KSM KSM
ACTIONEDBY
DRAWNK.SMRCEK DATE15-Apr-20
TITLE
ULCERTDRG-SEARCHLINEEXCELEDGERx
ATEX/IECExANDNORTHAMERICAN
CERTLABELDETAILS
2017E0052
SHT.1
OF1
Mod State: 1 2 3 4 5 6 7 8 9 10
Part No. SLXLESNGRX
Supply Voltage: 24V dc (18 to 32V max), Overvoltage Category II
Pmax: 15W (Ta -30°C), Pmax: 10W (Ta -30°C)
Contains Transmitter Module FCC ID HD5SFPMB
Contains Transmitter Module IC 1693BSFPMB
Contains Intrinsic Safety Circuits Ex ia: Um = 250V RMS
Intrinsically Safe - À Sécurité Intrinsèque
Patent: www.hsmpats.com
LEAKDETECTION
EQUIPMENT FOR USE IN
HAZARDOUS LOCATIONS
Serial No.
Serial No.
©2020LIFESAFETYDISTRIBUTION
GmbH.
ALLRIGHTSRESERVED.
THISDOCUMENTCONTAINSPROPRIETARY
INFORMATIONOFLIFESAFETY
DISTRIBUTIONGmbHANDITSAFFILIATED
COMPANIESANDISPROTECTEDBY
COPYRIGHTANDOTHERINTERNATIONAL
LAWS.REPRODUCTIONORIMPROPER
USEWITHOUTSPECIFICAUTHORIZATION
OFLIFESAFETYDISTRIBUTIONGmbHIS
STRICTLYFORBIDDEN.
TOLERANCESTOBEASSPECIFIED
BELOWUNLESSOTHERWISESTATED.
DIMS.2DP±0.1mm
1DP±0.25mm
NONE±0.4mm
ANGULAR±1/2°
HOLESØ0to8
+0.08
-0.0
Ø8to14
+0.1
-0.0
Ø14to25
+0.12
-0.0
UNLESSOTHERWISESTATED:
ALLDIMENSIONSINMILLIMETRESTO
APPLYAFTERPLATING.
ALLTHREADSTOBEBS3643.
REMOVEALLBURRSANDSHARPEDGES.

SURFACETEXTUREVALUESAREINm
RaANDTOBS 1134.
THISDRAWINGISTOBS8888.
IP66/67,
Type 4/4X
APPROVED
FOR PERFORMANCE ONLY
60079-29-4
DEMKO 20 ATEX 2281X / UL21UKEX2047X /
IECEx UL 20.0009X
(Ex d install) Ex db ia op is IIC T4 Gb (Ta 55°C to +75°C) or
(Ex de install) Ex db eb ia op is IIC T4 Gb (Ta 55°C to +75°C)
Ex ia op is tb IIIC T100°C Db (Ta 55°C to +75°C)
IP66/67
Supply Voltage: 24V dc (18 to 32V max), Overvoltage Category II
Pmax: 15W (Ta -30°C), Pmax: 10W (Ta -30°C)
Contains Intrinsic Safety Circuits Ex ia: Um = 250V RMS
Patent: www.hsmpats.com
THIS ITEM FORMS PART OF A CERTIFIED PRODUCT. NO
MODIFICATION PERMITTED WITHOUT REFERENCE TO CERTIFYING
AUTHORITY
Mod State: 1 2 3 4 5 6 7 8 9 10
A3
GYJ18.1482X
II 2 GD
2813
0518
DNV 21.0105 X
H
o
n
e
y
w
e
ll
A
n
a
ly
t
ic
s
L
td
.
,
P
o
o
le
,
D
o
r
s
e
t,
B
H
1
7
0
R
Z
M
a
d
e
i
n
U
K
S
e
a
r
c
h
l
i
n
e
E
x
c
e
l
E
d
g
e
-
O
p
e
n
P
a
t
h
F
l
a
m
m
a
b
l
e
G
a
s
L
e
a
k
D
e
t
e
c
t
o
r
-
R
e
c
e
i
v
e
r
Lire et comprendre le manuel avant d’installer, d’utiliser ou de réparer
l’équipement. La substitution des composants peut nuire à la sécurité
intrinsèque. Ne pas ouvrir l’équipement dans des atmosphères
contenant des explosifs. Scellez le conduit à moins de 50
mm. Risque potentiel de charge électrostatique,
voir les instructions.
WARNING / AVERTISSEMENT
H
o
n
e
y
w
e
ll
A
n
a
ly
t
ic
s
L
td
.
,
P
o
o
le
,
D
o
r
s
e
t,
B
H
1
7
0
R
Z
M
a
d
e
i
n
U
K
S
e
a
r
c
h
li
n
e
E
x
c
e
l
E
d
g
e
-
O
p
e
n
P
a
t
h
F
l
a
m
m
a
b
l
e
G
a
s
L
e
a
k
D
e
t
e
c
t
o
r
-
R
e
c
e
i
v
e
r
Read and understand manual before installation, operation or servicing. Substitution of
components may impair intrinsic safety. Do not open when an explosive atmosphere is
present. Potential electrostatic charging hazard, see instructions.
Não abra quando uma atmosfera explosiva estiver presente
Risco potencial de carga eletrostática
ver instruções.
WARNING / ATENÇÃO
Read and understand manual before installation, operating or servicing. Substitution of
components may impair intrinsic safety. Do not open when an explosive atmosphere is present.
Seal conduit within 50 mm. Potential electrostatic charging hazard, see manual.
Explosion protection
mark and equipment
group and category
CE mark
Conforms to all
applicable
European directives
Warning
Certified
ambient
temperature
Certification number
Serial number
Part number
Modification state
Certification code as
IEC / EN600790:
IEC / EN600791: and
IEC / EN 60079 - 28
cULus certification label
Searchline Excel Plus – Receiver Searchline Excel Edge – Receiver
2017E0050
THISDOCUMENTHASBEENGENERATEDUSINGINDESIGN
ANDMUSTONLYBEUPDATEDBYINDESIGN
Cl. I, Div.1, Gr. B,C,D, T4 (Ta 55°C to +75°C)
Cl. II, Div.1, Gr. E,F,G, T4 (Ta 55°C to +55°C)
Cl. III
Cl. I, Zn. 1 AEx db ia op is IIC T4 Gb (Ta 55°C to +75°C)
Cl. I, Zn. 1 AEx db eb ia op is IIC T4 Gb (Ta 55°C to +75°C)
Zn. 21 AEx ia op is tb IIIC T100°C Db (Ta 55°C to +55°C)
Ex db ia op is IIC T4 Gb X (Ta 55°C to +75°C)
Ex db eb ia op is IIC T4 Gb X (Ta 55°C to +75°C)
Ex ia op is tb IIIC T100°C Db X (Ta 55°C to +55°C)
Ø=72 mm
NOTES:
1.CERTIFICATIONLABELMATERIAL:STAINLESSSTEELSHEETMETALTOUNS S31603,THICKNESS0.2/0.6mm.
2.INTERNALWIRINGLABELMATERIAL:THERMALTRANSFERPOLYESTERLABEL
3.UNIQUESERIALNO:CONTAINSYEARDATAFORMONTHANDYEAROFMANUFACTURE.
4.OTHERMARKINGANDAGENCYDETAILSFORADDITIONALCERTIFICATIONSMAYBEADDED,NOTRATIFIEDBYUL.
North America (USA and Canada)ATEX / IECEx / INMETRO
Part No. XXXXXXXXX
FINISH
N/A
MATERIAL
SEENOTE1AND2
SCALE
1:1
05 04 03 02 01 ISSUE
31/05/21 16/02/21 11/02/21 09/12/20 15/04/20
DATE
CHANGE
KSM KSM KSM KSM KSM
ACTIONEDBY
DRAWNK.SMRCEK DATE15-Apr-20
TITLE
ULCERTDRG-SEARCHLINEEXCELPLUSRx
ATEX/IECExANDNORTHAMERICAN
CERTLABELDETAILS
2017E0050
SHT.1
OF1
Mod State: 1 2 3 4 5 6 7 8 9 10
Part No. XXXXXXXXX
Supply Voltage: 24V dc (18 to 32V max), Overvoltage Category II
Pmax: 15W (Ta -30°C), Pmax: 10W (Ta -30°C)
Contains Transmitter Module FCC ID HD5SFPMB
Contains Transmitter Module IC 1693BSFPMB
Contains Intrinsic Safety Circuits Ex ia: Um = 250V RMS
Intrinsically Safe - À Sécurité Intrinsèque
Patent: www.hsmpats.com
LEAKDETECTION
EQUIPMENT FOR USE IN
HAZARDOUS LOCATIONS
Serial No.
Serial No.
©2020LIFESAFETYDISTRIBUTION
GmbH.
ALLRIGHTSRESERVED.
THISDOCUMENTCONTAINSPROPRIETARY
INFORMATIONOFLIFESAFETY
DISTRIBUTIONGmbHANDITSAFFILIATED
COMPANIESANDISPROTECTEDBY
COPYRIGHTANDOTHERINTERNATIONAL
LAWS.REPRODUCTIONORIMPROPER
USEWITHOUTSPECIFICAUTHORIZATION
OFLIFESAFETYDISTRIBUTIONGmbHIS
STRICTLYFORBIDDEN.
TOLERANCESTOBEASSPECIFIED
BELOWUNLESSOTHERWISESTATED.
DIMS.2DP±0.1mm
1DP±0.25mm
NONE±0.4mm
ANGULAR±1/2°
HOLESØ0to8
+0.08
-0.0
Ø8to14
+0.1
-0.0
Ø14to25
+0.12
-0.0
UNLESSOTHERWISESTATED:
ALLDIMENSIONSINMILLIMETRESTO
APPLYAFTERPLATING.
ALLTHREADSTOBEBS3643.
REMOVEALLBURRSANDSHARPEDGES.

SURFACETEXTUREVALUESAREINm
RaANDTOBS 1134.
THISDRAWINGISTOBS8888.
DNV 21.0105 X
DEMKO 20 ATEX 2281X / UL21UKEX2047X /
IECEx UL 20.0009X
(Ex d install) Ex db ia op is IIC T4 Gb (Ta 55°C to +75°C) or
(Ex de install) Ex db eb ia op is IIC T4 Gb (Ta 55°C to +75°C)
Ex ia op is tb IIIC T100°C Db (Ta 55°C to +75°C)
IP66/67
Supply Voltage: 24V dc (18 to 32V max), Overvoltage Category II
Pmax: 15W (Ta -30°C), Pmax: 10W (Ta -30°C)
Contains Intrinsic Safety Circuits Ex ia: Um = 250V RMS
Patent: www.hsmpats.com
THISITEMFORMSPARTOFACERTIFIEDPRODUCT.NO
MODIFICATIONPERMITTEDWITHOUTREFERENCETOCERTIFYING
AUTHORITY
Mod State: 1 2 3 4 5 6 7 8 9 10
A3
GYJ18.1482X
IP66/67,
Type 4/4X
APPROVED
FOR PERFORMANCE ONLY
60079-29-4
II 2 GD
2813
0518
H
o
n
e
y
w
e
ll
A
n
a
ly
t
ic
s
L
td
.
,
P
o
o
le
,
D
o
r
s
e
t,
B
H
1
7
0
R
Z
M
a
d
e
i
n
U
K
H
o
n
e
y
w
e
ll
A
n
a
ly
t
ic
s
L
td
.
,
P
o
o
le
,
D
o
r
s
e
t,
B
H
1
7
0
R
Z
M
a
d
e
i
n
U
K
S
e
a
r
c
h
l
i
n
e
E
x
c
e
l
P
l
u
s
-
O
p
e
n
P
a
t
h
F
l
a
m
m
a
b
l
e
G
a
s
L
e
a
k
D
e
t
e
c
t
o
r
-
R
e
c
e
i
v
e
r
S
e
a
r
c
h
l
i
n
e
E
x
c
e
l
P
l
u
s
-
O
p
e
n
P
a
t
h
F
l
a
m
m
a
b
l
e
G
a
s
L
e
a
k
D
e
t
e
c
t
o
r
-
R
e
c
e
i
v
e
r
Lire et comprendre le manuel avant d’installer, d’utiliser ou de réparer
l’équipement. La substitution des composants peut nuire à la sécurité
intrinsèque. Ne pas ouvrir l’équipement dans des atmosphères
contenant des explosifs. Scellez le conduit à moins de 50
mm. Risque potentiel de charge électrostatique,
voir les instructions.
Read and understand manual before installation, operation or servicing. Substitution of
components may impair intrinsic safety. Do not open when an explosive atmosphere is
present. Potential electrostatic charging hazard, see instructions.
Não abra quando uma atmosfera explosiva estiver presente
Risco potencial de carga eletrostática
ver instruções.
WARNING / AVERTISSEMENT
WARNING / ATENÇÃO
Read and understand manual before installation, operating or servicing. Substitution of
components may impair intrinsic safety. Do not open when an explosive atmosphere is present.
Seal conduit within 50 mm. Potential electrostatic charging hazard, see manual.
Equipment group and
category
Warning
Certified
ambient
temperature
Explosion protection
mark and certification
number
Serial number
Part number
Modification state
2017E0052
THISDOCUMENTHASBEENGENERATEDUSINGINDESIGN
ANDMUSTONLYBEUPDATEDBYINDESIGN
Cl. I, Div.1, Gr. B,C,D, T4 (Ta 55°C to +75°C)
Cl. II, Div.1, Gr. E,F,G, T4 (Ta 55°C to +55°C)
Cl. III
Cl. I, Zn. 1 AEx db ia op is IIC T4 Gb (Ta 55°C to +75°C)
Cl. I, Zn. 1 AEx db eb ia op is IIC T4 Gb (Ta 55°C to +75°C)
Zn. 21 AEx ia op is tb IIIC T100°C Db (Ta 55°C to +55°C)
Ex db ia op is IIC T4 Gb X (Ta 55°C to +75°C)
Ex db eb ia op is IIC T4 Gb X (Ta 55°C to +75°C)
Ex ia op is tb IIIC T100°C Db X (Ta 55°C to +55°C)
Ø=72 mm
NOTES:
1.CERTIFICATIONLABELMATERIAL:STAINLESSSTEELSHEETMETALTOUNS
S31603,THICKNESS0.2/0.6mm.
2.INTERNALWIRINGLABELMATERIAL:THERMALTRANSFERPOLYESTERLABEL
3.UNIQUESERIALNO:CONTAINSYEARDATAFORMONTHANDYEAROFMANUFACTURE.
4.OTHERMARKINGANDAGENCYDETAILSFORADDITIONALCERTIFICATIONSMAYBEADDED,NOTRATIFIEDBYUL.
North America (USA and Canada)ATEX / IECEx / INMETRO
Part No. XXXXXXXXX
FINISH
N/A
MATERIAL
SEENOTE1AND2
SCALE
1:1
04 03 02 01 ISSUE
02/06/21 11/02/21 09/12/20 15/04/20
DATE
CHANGE
KSM KSM KSM KSM
ACTIONEDBY
DRAWNK.SMRCEK DATE15-Apr-20
TITLE
ULCERTDRG-SEARCHLINEEXCELEDGERx
ATEX/IECExANDNORTHAMERICAN
CERTLABELDETAILS
2017E0052
SHT.1
OF1
Mod State: 1 2 3 4 5 6 7 8 9 10
Part No. SLXLESNGRX
Supply Voltage: 24V dc (18 to 32V max), Overvoltage Category II
Pmax: 15W (Ta -30°C), Pmax: 10W (Ta -30°C)
Contains Transmitter Module FCC ID HD5SFPMB
Contains Transmitter Module IC 1693BSFPMB
Contains Intrinsic Safety Circuits Ex ia: Um = 250V RMS
Intrinsically Safe - À Sécurité Intrinsèque
Patent: www.hsmpats.com
LEAKDETECTION
EQUIPMENT FOR USE IN
HAZARDOUS LOCATIONS
Serial No.
Serial No.
©2020LIFESAFETYDISTRIBUTION
GmbH.
ALLRIGHTSRESERVED.
THISDOCUMENTCONTAINSPROPRIETARY
INFORMATIONOFLIFESAFETY
DISTRIBUTIONGmbHANDITSAFFILIATED
COMPANIESANDISPROTECTEDBY
COPYRIGHTANDOTHERINTERNATIONAL
LAWS.REPRODUCTIONORIMPROPER
USEWITHOUTSPECIFICAUTHORIZATION
OFLIFESAFETYDISTRIBUTIONGmbHIS
STRICTLYFORBIDDEN.
TOLERANCESTOBEASSPECIFIED
BELOWUNLESSOTHERWISESTATED.
DIMS.2DP±0.1mm
1DP±0.25mm
NONE±0.4mm
ANGULAR±1/2°
HOLESØ0to8
+0.08
-0.0
Ø8to14
+0.1
-0.0
Ø14to25
+0.12
-0.0
UNLESSOTHERWISESTATED:
ALLDIMENSIONSINMILLIMETRESTO
APPLYAFTERPLATING.
ALLTHREADSTOBEBS3643.
REMOVEALLBURRSANDSHARPEDGES.

SURFACETEXTUREVALUESAREINm
RaANDTOBS 1134.
THISDRAWINGISTOBS8888.
IP66/67,
Type 4/4X
APPROVED
FOR PERFORMANCE ONLY
60079-29-4
DEMKO 20 ATEX 2281X / UL21UKEX2047X /
IECEx UL 20.0009X
(Ex d install) Ex db ia op is IIC T4 Gb (Ta 55°C to +75°C) or
(Ex de install) Ex db eb ia op is IIC T4 Gb (Ta 55°C to +75°C)
Ex ia op is tb IIIC T100°C Db (Ta 55°C to +75°C)
IP66/67
Supply Voltage: 24V dc (18 to 32V max), Overvoltage Category II
Pmax: 15W (Ta -30°C), Pmax: 10W (Ta -30°C)
Contains Intrinsic Safety Circuits Ex ia: Um = 250V RMS
Patent: www.hsmpats.com
THIS ITEM FORMS PART OF A CERTIFIED PRODUCT. NO
MODIFICATION PERMITTED WITHOUT REFERENCE TO CERTIFYING
AUTHORITY
Mod State: 1 2 3 4 5 6 7 8 9 10
A3
GYJ18.1482X
II 2 GD
2813
0518
DNV 21.0105 X
H
o
n
e
y
w
e
ll
A
n
a
ly
t
ic
s
L
td
.
,
P
o
o
le
,
D
o
r
s
e
t,
B
H
1
7
0
R
Z
M
a
d
e
i
n
U
K
S
e
a
r
c
h
l
i
n
e
E
x
c
e
l
E
d
g
e
-
O
p
e
n
P
a
t
h
F
l
a
m
m
a
b
l
e
G
a
s
L
e
a
k
D
e
t
e
c
t
o
r
-
R
e
c
e
i
v
e
r
Lire et comprendre le manuel avant d’installer, d’utiliser ou de réparer
l’équipement. La substitution des composants peut nuire à la sécurité
intrinsèque. Ne pas ouvrir l’équipement dans des atmosphères
contenant des explosifs. Scellez le conduit à moins de 50
mm. Risque potentiel de charge électrostatique,
voir les instructions.
WARNING / AVERTISSEMENT
H
o
n
e
y
w
e
ll
A
n
a
ly
t
ic
s
L
td
.
,
P
o
o
le
,
D
o
r
s
e
t,
B
H
1
7
0
R
Z
M
a
d
e
i
n
U
K
S
e
a
r
c
h
li
n
e
E
x
c
e
l
E
d
g
e
-
O
p
e
n
P
a
t
h
F
l
a
m
m
a
b
l
e
G
a
s
L
e
a
k
D
e
t
e
c
t
o
r
-
R
e
c
e
i
v
e
r
Read and understand manual before installation, operation or servicing. Substitution of
components may impair intrinsic safety. Do not open when an explosive atmosphere is
present. Potential electrostatic charging hazard, see instructions.
Não abra quando uma atmosfera explosiva estiver presente
Risco potencial de carga eletrostática
ver instruções.
WARNING / ATENÇÃO
Read and understand manual before installation, operating or servicing. Substitution of
components may impair intrinsic safety. Do not open when an explosive atmosphere is present.
Seal conduit within 50 mm. Potential electrostatic charging hazard, see manual.
Equipment group and
category
Warning
Certified
ambient
temperature
Explosion protection
mark and certification
number
Serial number
Part number
Modification state
12.6EU Declaration of Conformity
SIMPLIFIED EU DECLARATION of CONFORMITY
Hereby and as of the date of this publication, Honeywell declares that the Searchline Excel equipment is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of conformity is available at: www.sps.honeywell.com

Table of Contents

Other manuals for Honeywell SEARCHLINE EXCEL PLUS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell SEARCHLINE EXCEL PLUS and is the answer not in the manual?

Honeywell SEARCHLINE EXCEL PLUS Specifications

General IconGeneral
BrandHoneywell
ModelSEARCHLINE EXCEL PLUS
CategoryGas Detectors
LanguageEnglish

Related product manuals