Confi
g
uration S
y
stem clock confi
g
ured
Exam
p
le
If the original system clock is in the daylight
saving time range, the system clock configured is
the original system clock + “summer-offset."
Configure: clock summer-time ss one-off
00:30 2005/1/1 1:00 2005/8/8 2
System clock configured:: 03:00:00 ss
Sat 01/01/2005
If the the original system clock +
summer-offset” is not in the daylight
saving time range, the system clock
configured is the original system clock.
After this configuration, if you disable
the daylight saving, the system clock
becomes the system clock minus
summer-offset."
1 and 3
If “date-time” is not in the daylight saving time
range, the system clock configured is
date-time."
Configure: clock datetime 1:00
2007/1/1 and clock summer-time ss
one-off 1:00 2006/1/1 1:00
2006/8/8 2
System clock configured:: 01:00:00
UTC Mon 01/01/2007
If “date-time” is in the daylight saving time range,
the system clock configured is “date-time +
summer-offset."
Configure: clock datetime 8:00
2007/1/1 and clock summer-time ss
one-off 1:00 2007/1/1 1:00
2007/8/8 2
System clock configured:: 10:00:00 ss
Mon 01/01/2007
If “date-time + “summer-offset”is not in
the daylight saving time range, the
system clock configured is “date-time."
After this configuration, if you disable
the daylight saving, the system clock
becomes the system clock minus
summer-offset."
[1], 3 and 1
If “date-time” is not in the daylight saving time
range, the system clock configured is
date-time."
Configure: clock summer-time ss one-off
1:00 2007/1/1 1:00 2007/8/8 2
and clock datetime 1:00 2008/1/1
System clock configured:: 01:00:00
UTC Tue 01/01/2008
date-time” is in the daylight saving time range:
If the value of “date-time - summer -offset” is not
in the summer-time range, the system clock
configured is “date-time - summer-offset”;
If the value of “date-time- summer- offset” is in
the summer-time range, the system clock
configured is “date-time."
Configure: clock summer-time ss one-off
1:00 2007/1/1 1:00 2007/8/8 2
and clock datetime 1:30 2007/1/1
System clock configured:: 23:30:00
UTC Sun 12/31/2006
Configure: clock summer-time ss one-off
1:00 2007/1/1 1:00 2007/8/8 2
and clock datetime 3:00 2007/1/1
System clock configured: 03:00:00 ss
Mon 01/01/2007

Table of Contents

Other manuals for HP A5800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP A5800 Series and is the answer not in the manual?

HP A5800 Series Specifications

General IconGeneral
BrandHP
ModelA5800 Series
CategorySwitch
LanguageEnglish

Related product manuals