EasyManuals Logo
Home>HP>Server>ProLiant series

HP ProLiant series User Manual

HP ProLiant series
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #116 background imageLoading...
Page #116 background image
Error messages 116
Real-Time Clock Battery Failing
Event Type: System configuration battery low
Action: Replace the system configuration battery.
System AC Power Overload (Power Supply X)
Event Type: Power supply overload
Action:
1. Switch the voltage from 110 V to 220 V or add an additional power supply (if applicable to the
system).
2. If the problem persists, remove some of the installed options.
System AC Power Problem (Power Supply X)
Event Type: AC voltage problem
Action: Check for any power source problems.
System Fan Failure (Fan X, Location)
Event Type: Fan failure
Action: Replace the fan.
System Fans Not Redundant
Event Type: Fans not redundant
Action: Add a fan or replace the failed fan.
System Overheating (Zone X, Location)
Event Type: Overheating condition
Action: Check fans.
System Power Supplies Not Redundant
Event Type: Power supply not redundant
Action: Add a power supply or replace the failed power supply.
System Power Supply Failure (Power Supply X)
Event Type: Power supply failure
Action: Replace the power supply.
Unrecoverable Host Bus Data Parity Error...
...Unrecoverable Host Bus Address Parity Error

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant series and is the answer not in the manual?

HP ProLiant series Specifications

General IconGeneral
BrandHP
ModelProLiant series
CategoryServer
LanguageEnglish

Related product manuals