Edge Switch 2/24 installation guide 55
• Threshold criteria:
• Percent traffic capacity utilized—The percent of the port’s throughput capacity achieved by
the measured throughput. This setting constitutes the threshold value. For example a value of
50 means that the port’s threshold is reached when throughput is 50% of capacity.
• Time interval during which throughput is measured and alert notification can occur.
• The maximum cumulative time that the throughput percentage threshold can be exceeded
during the set time interval before an alert is generated.
• Ports for which you are configuring threshold alerts.
You can configure up to 16 alerts, and any number of alerts can be active at one time. Use the
following procedures to create a new threshold alert, or to modify, activate, deactivate, or delete an
alert.
Create new alerts
1. At the Hardware View page, select Configure > Threshold Alerts. The Configure Threshold Alerts
dialog box is displayed, as shown in Figure 25.
NOTE: If alerts are configured, they will display in table format showing the name of the
alert, type of alert (Rx, Tx, or Rx or Tx), and alert state (inactive or active).
Figure 25 Configure Threshold Alerts dialog box