Alarm
Create Default
Event
Select whether to create a default event.
The description of the default event is default event, the action is log-and-trap,
and the owner is default owner.
If there is no event, you can select to create the default event. And when the value
of the alarm variable is higher than the alarm rising threshold or lower than the
alarm falling threshold, the system will adopt the default action, that is,
log-and-trap.
Rising
Threshold
Set the alarm rising threshold.
Rising Event
Set the action that the system will take when the value of the alarm variable is
higher than the alarm rising threshold.
If the Create Default Event check box is selected, this option is not configurable.
Falling
Threshold
Set the alarm falling threshold.
Falling Event
Set the action that the system will take when the value of the alarm variable is
lower than the alarm falling threshold.
If the Create Default Event check box is selected, this option is not configurable.
Return to RMON alarm configuration task list.
Displaying RMON statistics information
Select Device > RMON from the navigation tree to enter the page of the Statistics tab, as shown in Figure
77. Click the
icon of a statistics entry to enter the page as shown in Figure 85, which displays all
statistics items on the current interface.