OperatiOn
HPR800XD Auto Gas 806500 4-25
Additional improvements
Additional improvements
Some of these improvements involve trade-offs, as described.
Piercing
The pierce delay should allow sufficient time to penetrate the full thickness of the material, but not so long that it allows
the arc to “wander” while trying to find the edge of a large pierce hole. As consumables wear, this delay time may need
to be increased. Pierce delay times given in the cut charts are based on average delay times throughout the life of the
consumables.
Using the “pierce complete” signal during piercing maintains the shield-gas pressure at the higher preflow pressure,
which provides additional protection for the consumables (for example: 30 amp O
2
/O
2
and 50 amp O
2
/O
2
processes).
The pierce complete signal must be turned off for processes with shield gas preflow pressures that are lower than the
cutflow pressures (for example: 600 amp and 800 amp processes).
When piercing materials close to the maximum thickness for a specific process, there are several important factors to
consider:
• Allowalead-indistancethatisaboutthesameasthethicknessofthematerialbeingpierced.50mm(2in)
material requires a 50 mm lead-in.
• Toavoiddamagetotheshieldfromthebuildupofmoltenmaterialcreatedbythepierce,donotallowthetorch
to descend to cut height until it has cleared the puddle of molten material.
• When pre-piercing with the 400 amp O
2
/air process, the arc should be on for a minimum of 4 seconds or the
electrode may experience rapid wear. This 4 seconds allows the current to properly ramp-up and ramp-down
which is required for the long life process. A small torch movement may be necessary if the peirce time is less
than 4 seconds to keep the arc transferred to the plate.
• Differentmaterialchemistriescanhaveanadverseeffectonthepiercecapabilityofthesystem.Inparticular,
high-strength steel and steel with a high manganese or silicon content can reduce the maximum pierce
capability. Hypertherm calculates mild steel pierce parameters with certified A-36 plate.
• Ifthesystemhasdifficultypiercingaspecificmaterialorthickness,increasingtheshieldpreflowpressurecan
help in some cases.
Trade-off: This may reduce starting reliability.
• Usinga“movingpierce”or“flyingpierce”(startingtorchmotionimmediatelyaftertransferandduringthepierce
process) can extend the piercing capability of the system in some cases. Because this can be a complex
process that can damage the torch, lifter, or other components, an edge start is recommended unless the
operator is experienced with this technique.
How to increase cutting speed
• Decreasethetorch-to-workdistance.
Trade-off: This will increase the negative cut angle.
Note: The torch must not touch the workpiece while piercing or cutting.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR800XD and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR800XD Specifications

General IconGeneral
BrandHypertherm
ModelHyPerformance Plasma HPR800XD
CategoryCutter
LanguageEnglish

Related product manuals