InstallatIon
HPR800XD Auto Gas – 806500 3-11
Placement of the primary power supply
A
The power supply can be moved by forklift but the forks must be long enough to extend the entire length of the base.
Take care when lifting so that the underside of the power supply is not damaged. The forks must also be centered front
to back and side to side to prevent tipping while moving. Fork lift speeds should be kept to a minimum, especially when
making a turn or going around a corner.
• Place the power supply in an area that is free of excessive moisture, has proper ventilation and is relatively clean.
Allow 1 m (3 ft) of space on all sides of the power supply for ventilation and service.
• Coolingairisdrawninthroughthefrontpanelandisexhaustedthroughtherearoftheunitbyacooling
fan. Donot place any filter device over the air intake locations, which reduces cooling efficiency and VOIDS
THEWARRANTY.
• Donotplacethepowersupplyonaninclinegreaterthan10°topreventitfromtoppling.
HPR400XD power supplies with serial number HPR400-000560 or later can be upgraded to a HPR800XD
primary or secondary power supply.
DANGER
ELECTRIC SHOCK CAN KILL
Remove all electrical connections to the power supply before moving or positioning. Transporting the
unit can cause personal injury and equipment damage.