3-58 HPR800XD Auto Gas 806500
Custom Coolant mix for cold operating temperatures
10/16/08
Custom Coolant mix for cold operating temperatures
• Ambient temperature below -12° C / 10° F
• Chiller process temperature below 4° C / 39° F
CAUTION
For operating temperatures colder than the temperature stated above, the percentage of propylene
glycol must be increased. Failure to do so could result in a cracked torch head, hoses, or other damage
to the torch coolant system due to freezing.
Use the chart below to determine what percentage of propylene glycol to use in the mixture.
Mix 100% glycol (028873) with the premixed Hypertherm coolant (028872) to increase the percentage of glycol.
The 100% glycol solution can also be mixed with purifi ed water (see the chart below for water purity requirements) to
achieve the required protection from freezing.
Note: The maximum percentage of glycol should never exceed 50%. Increasing the percentage of glycol reduces
the capacity of the cooling system.
Hypertherm pre-mix (028872)
Maximum glycol percentage
0
0
0
0
0
0
0
0
-7
-6
-5
-4
-3
-2
-1
10
20
30
40
0102030405
06
0
-57
-51
-46
-40
-34
-29
-23
-18
-12
-7
-1
4
Freezing point
% of propylene glycol
Freezing point of propylene glycol solution Solution
°F°C

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR800XD and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR800XD Specifications

General IconGeneral
BrandHypertherm
ModelHyPerformance Plasma HPR800XD
CategoryCutter
LanguageEnglish

Related product manuals