Install and Set Up the Plasma Power Supply
34 810470 Operator Manual Powermax65/85/105 SYNC
Acoustical noise levels
This plasma system can make more than the permitted acoustical noise levels as defined by national
and local codes. Always put on correct ear protection when cutting or gouging. Any acoustical
noise measurements taken are related to the specific environment in which the system is used.
Refer to Noise can damage hearing in the Safety and Compliance Manual (80669C).
In addition, you can find an Acoustical Noise Data Sheet for your system at
www.hypertherm.com/docs. In the search box, enter data sheet.
Radio frequency identification (RFID) specifications
The Hypertherm RFID near-field wireless communication system contains the following
components:
A passive RFID tag in the Hypertherm cartridge
A wireless radio transceiver on the printed circuit board (PCB) in the SmartSYNC torch:
Operating frequency: 13.56 MHz
Protocol: ISO/IEC 15693
Maximum range: 8 mm (0.32 inch)
Maximum transmit power: 104 mW