EasyManuals Logo
Home>Hypertherm>Welding System>SYNC Powermax 85

Hypertherm SYNC Powermax 85 User Manual

Hypertherm SYNC Powermax 85
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Install and Set Up the Plasma Power Supply
2
Powermax65/85/105 SYNC Operator Manual 810470 49
Powermax85 SYNC systems
Table 5 – 85 A CSA
Table 6 – 85 A CE/CCC
Extension cord length
< 3 m
(< 10 ft)
3 m – 7.5 m
(10 ft – 25 ft)
7.5 m – 15 m
(25 ft – 50 ft)
15 m 30 m
(50 ft – 100 ft)
30 m – 45 m
(100 ft – 150 ft)
Input voltage (VAC) Phase Extension cord gauge
200 – 240 1
16 mm
2
(6 AWG)
16 mm
2
(6 AWG)
16 mm
2
(6 AWG)
25 mm
2
(4 AWG)
35 mm
2
(2 AWG)
480 1
6mm
2
(10 AWG)
6mm
2
(10 AWG)
6mm
2
(10 AWG)
10 mm
2
(8 AWG)
10 mm
2
(8 AWG)
200 – 240 3
10 mm
2
(8 AWG)
10 mm
2
(8 AWG)
10 mm
2
(8 AWG)
16 mm
2
(6 AWG)
25 mm
2
(4 AWG)
400/480 3
6mm
2
(10 AWG)
6mm
2
(10 AWG)
6mm
2
(10 AWG)
6mm
2
(10 AWG)
6mm
2
(10 AWG)
600 3
6mm
2
(10 AWG)
6mm
2
(10 AWG)
6mm
2
(10 AWG)
6mm
2
(10 AWG)
6mm
2
(10 AWG)
Extension cord length
< 3 m
(< 10 ft)
3 m – 7.5 m
(10 ft – 25 ft)
7. 5 m 15 m
(25 ft – 50 ft)
15 m – 30 m
(50 ft – 100 ft)
30 m – 45 m
(100 ft – 150 ft)
Input voltage (VAC) Phase Extension cord gauge
380 3 6 mm
2
6mm
2
6mm
2
6mm
2
6mm
2
400 3 6 mm
2
6mm
2
6mm
2
6mm
2
6mm
2

Table of Contents

Other manuals for Hypertherm SYNC Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm SYNC Powermax 85 and is the answer not in the manual?

Hypertherm SYNC Powermax 85 Specifications

General IconGeneral
BrandHypertherm
ModelSYNC Powermax 85
CategoryWelding System
LanguageEnglish

Related product manuals