Operate the Plasma System
88 810470 Operator Manual Powermax65/85/105 SYNC
Gas pressure indicators
For instructions on how to manually change the gas pressure, refer to page 76.
Fault codes and fault icons
When a fault occurs with the plasma power supply or the torch, a fault code and related fault
icon show on the status screen. For information on what each fault code means and how to
remove it, refer to Fault codes on page 130.
Gas pressure bar – This icon shows a visual indicator of the gas pressure when you
are in manual gas pressure mode.
The midpoint of the vertical bar identifies the automatic pressure setting that is
set by the plasma power supply. The arrow shows the manual pressure setting,
as follows:
When you increase (+) the gas pressure from the set value, the arrow goes
above the midpoint.
When you decrease (-) the gas pressure from the set value, the arrow goes
below the midpoint.
Gas pressure setting – The gas pressure shows in bar and psi when you are in
manual gas pressure mode.
Selection cursor – This icon shows whether amperage or gas pressure is selected
when you are in manual gas pressure mode.