Install and Set Up the Plasma Power Supply
2
44 810470 Operator Manual Powermax65/85/105 SYNC
Powermax105 SYNC
CSA configurations (3-phase)
230 V – 400 V CE configurations (3-phase)
380 V CCC / 400 V CE configurations (3-phase)
Input voltage at 50Hz/60Hz* 200V 208V 240V 480V 600V
Input current at rated output
(105 A x 160 VDC = 16.8 kW)
58 A 56 A 49 A 25 A 22 A
Input current during arc stretch 82 A 82 A 78 A 40 A 35 A
Fuse (time-delay) 80 A 80 A 80 A 40 A 40 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50Hz/60Hz* 230V 400V
Input current at rated output (105 A x 160 VDC = 16.8 kW) 50 A 29 A
Input current during arc stretch 80 A 46 A
Fuse (time-delay) 80 A 50 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50 Hz/60 Hz* CCC 380 V CE 400 V
Input current at rated output (105 A x 160 VDC = 16.8 kW) 30 A 28 A
Input current during arc stretch 42 A 44 A
Fuse (time-delay) 50 A 50 A
* All models have a voltage tolerance of +10% / -15%.

Table of Contents

Other manuals for Hypertherm SYNC Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm SYNC Powermax 85 and is the answer not in the manual?

Hypertherm SYNC Powermax 85 Specifications

General IconGeneral
BrandHypertherm
ModelSYNC Powermax 85
CategoryWelding System
LanguageEnglish

Related product manuals