160
TROUBLESHOOTING
14
If your transceiver seems to be malfunctioning, please check the following points before sending it to a service center.
PROBLEM POSSIBLE CAUSE SOLUTION REF.
Transceiver will not power
ON.
The batteries are exhausted.
Loose connection of a battery pack (case).
The battery polarity is reversed.
• Replace the batteries or charge the battery pack.
• Clean battery terminals.
• Check the battery polarity.
pgs. 2, 12–14
p. 14
p. 14
No sound comes from the
speaker.
Volume level is too low.
External speaker is connected or cloning
cable is inserted.
• Push [] or [] to suitable level.
Check the external speaker connection or remove the
cloning cable.
p. 16
Transmitting is impossible. The batteries are exhausted.
A frequency outside of the 144/430 MHz
amateur bands is set.
• Replace the batteries or charge the battery pack.
Reset the frequency within 144/430 MHz amateur
bands.
pgs. 2, 12–14
pgs. 20, 161
No contact possible with
another station.
Different tone is selected with tone/DTCS
squelch.
• Check the tone/DTCS using tone scan. p. 152
Frequency cannot be set. • The lock function is activated.
• Memory mode or call channel is selected.
• Push
[MENU ] for 1 sec. to cancel the function.
• Push [V/MHz] to set the VFO mode.
p. 24
p. 18
Program scan function
cannot start.
Memory mode or call channel is selected.
Same frequencies are programmed both
1A” and “1B” of PROGRAM-CH.
• Push [V/MHz] to set the VFO mode.
Programming different frequencies in 1A” and 1B”
respectively.
p. 18
p. 105
Memory scan function
cannot start.
The VFO mode or call channel is selected.
The programmed memory channel is only
one.
• Push [M/CALL] to select memory mode.
• Program 2 or more memory channels.
p. 18
p. 94
The displayed frequency is
erroneous.
The CPU malfunctioned.
• External factors caused a fault.
• Reset the transceiver.
Remove and reattach the battery pack or battery
case.
pgs. 158, 159
p. 2
Cannot charge the battery
with BC-139 (LED blinks
orange).
The transceiver's power is ON.
The battery pack is fault electric discharge.
Turn the transceiver’s power OFF, or insert only the
battery pack into the BC-139 to charge it.
The battery pack is charged alone (without the trans-
ceiver) or regular charge is carried out.
p. 13
pgs. 12, 13

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-E80D and is the answer not in the manual?