FX-1/FX-1R Maintenance Manual
DANGER
To prevent any trouble caused by accidental machine start, always
shut-down the power before starting the maintenance and
adjustment work.
[9] PNEUMATIC UNITS
9-1. Replacing the Main Pressure Detection Cable Assembly
(1) Detach the pressure gauge from the cover FBL.
(2) Disconnect the connector.
(3) Reassemble the components in the reverse order of disassembly.
<CAUTION>
Before replacing the pressure detection cable assembly, always close the knob of the
finger valve.
Check that the green arrow on the pressure gauge indicates 0.4 MPa (4kgf/cm
2
).
If adjustment is necessary, turn the adjustment knob on the pressure gauge using a
flat-blade screwdriver.
Pressure adjustment knob
9-1
Rev. 2.00