Measure the belt tension using UNITTA’s belt tension meter.
The following shows the set values.
WEIGHT 0.025
WIDTH 009.0
SPAN 0070
Adjust the belt tension to 45N±5N.
14-3. Mounting the Origin Switch Dog
SL6030692TN
BRKT FIX BOLT ×2
SL6030692TN
DOG FIX BOLT×2
RAIL STAND RR
E4801729000
AWC SENSOR BRKT
L813E1310A0
AWCS NEAR SENSOR ASM
E2156725000
AWC SENSOR DOG
RAIL PLATE RR
E2156725000
AWC SENSOR DOG
E4801729000
AWC SENSOR BRKT
Figure 14-3-1
Adjust the clearance between the sensor and dog to 1 mm.
Adjust the dog position so that the sensor is turned ON when the PWB width is 361 mm.
After the AWC OP dog has been mounted, change the rail width between the maximum
and minimum levels to check that it does not interfere with other objects, such as the air
tube.
14-3
Rev. 2.00