KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance Manual
9-8
9-7. Replacing the Bank-Up Detection Sensor (Optional Replacement
Table)
(1) Turn off the power to the main unit.
(2) Lower the lifter.
(3) Loosen the fixing screws, remove the sensor and replace it with a new one.
(4) Reassemble the components in the reverse order of disassembly.
<Adjustment>
c Turn on the power to the main unit.
d Make sure that there is a 1mm gap between the bank sensor dog and sensor as shown
below.
1
Figure 9-7-1
Rev. 2.00