KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance Manual
15-12
15-9. Mounting the BU-Pin Sensor Dog
This work is required only for the machines with L-size or E-size specifications.
Assemble the parts to the stopper assembly following the figure below. (Perform the steps (1) to (3) in
this order.)
1
2
(2) Mount the 40019212 BU_pin sensor dog in the
hole from which the tie-up band has been
removed. Note that the orientation varies
according to the transferring direction. Assemble
so that the bent part faces the stop sensor.
(1) Cut the tie-up
band. (Be careful
not to damage the
sensor cable.)
(3) Fix the BU_pin
sensor dog by the
SM4030501SN.
Path of the stop sensor cable after the
BU_pin sensor dog mounted
Rev. 2.00