KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance Manual
1-15
1-4-3. Clearance between the Sensor Head and the Y-axis Linear Way (for Y-axis only)
c Put a 0.5-mm clearance gauge in the clearance between the Y-axis linear way and sensor
head, and check that no play exists and that the clearance gauge is inserted smoothly.
d If the clearance is not 0.5 mm in the check in c above, loosen the screw fixing the sensor
bracket (screw d shown in the figure below).
e Put a 0.5-mm clearance gauge in the clearance between the Y-axis linear way and sensor
head, and then tighten the screw again.
f Carry out the check stated in above c above.
Sensor head
Magnescale
Screwc
Screwd
Clearance between the sensor head and the Y-axis linear way: 0.5
± 0.1 mm (for Y-axis only)
Rev. 2.00