EasyManuals Logo
Home>Juniper>Switch>EX4200 Series

Juniper EX4200 Series User Manual

Juniper EX4200 Series
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #170 background imageLoading...
Page #170 background image
1. Connect one end of the grounding cable to a proper earth ground, such as the rack
in which the switch is mounted.
2. Place the grounding lug attached to the grounding cable over the protective earthing
terminal. See Figure 52 on page 141.
3. Secure the grounding lug to the protective earthing terminal with screws.
4. Dress the grounding cable and ensure that it does not touch or block access to other
switch components and that it does not drape where people could trip over it.
Connecting Earth Ground to an EX8216 Switch
There are two protective earthing terminals on an EX8216 switch: one on the left side of
the chassis and the other on the rear of the chassis. Only one of the two protective earthing
terminals needs to be permanently connected to earth ground.
An AC-powered EX Series switch chassis gets additional grounding when you plug the
power supply in the switch into a grounded AC power outlet by using an AC power cord
appropriate for your geographical location. See AC Power Cord Specifications for an
EX8200 Switch.
Ensure that you have the following parts and tools available:
•
Grounding cable for your EX8216 switch—The grounding cable must be 2 AWG
(33.6 mm²), minimum 60°C wire, or as permitted by the local code.
•
Grounding lug for your grounding cable. See Grounding Cable and Lug Specifications
for EX8200 Switches.
•
Washersand ¼-20x.5/8-in. screws to secure the grounding lug to the protective earthing
terminal
•
Phillips (+) screwdriver, number 2
To connect earth ground to an EX8216 switch:
1. Connect one end of the grounding cable to a proper earth ground, such as the rack
in which the switch is mounted.
2. Place the grounding lug attached to the grounding cable over the protective earthing
terminal. See Figure 52 on page 141.
3. Secure the grounding lug to the protective earthing terminal with screws.
4. Dress the grounding cable and ensure that it does not touch or block access to other
switch components and that it does not drape where people could trip over it.
Related Topics Connecting AC Power to an EX2200 Switch•
• Connecting AC Power to an EX3200 or EX4200 Switch on page 147
• Connecting DC Power to an EX3200 or EX4200 Switch on page 149
• Connecting AC Power to an EX4500 Switch
• Connecting AC Power to an EX8200 Switch
Copyright © 2010, Juniper Networks, Inc.146
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4200 Series and is the answer not in the manual?

Juniper EX4200 Series Specifications

General IconGeneral
BrandJuniper
ModelEX4200 Series
CategorySwitch
LanguageEnglish

Related product manuals