Model 2100 6 1/2-Digit Resolution Digital Multimeter User’s Manual Section 4: Front Panel Operations
To set the resolution from the front panel:
Method A:
1. Select the desired measurement function by pressing one of the function keys located on
the first row of your meter's front panel (the locations of the keys are shown with red frames
in Figure 4-3).
2. Press the DIGITS key to select the resolution for your measurement. You can press the
DIGITS key several times to see how the resolution setting changes from 4 1/2, 5 1/2, to 6
1/2.
NOTE When using Method A to set the resolution, your options are 4 1/2 (slow), 5 1/2 (slow),
and 6 1/2 (fast).
Method B:
1. Press the CONFIG key and select one of the following functions: DCV, DCI (SHIFT + DCV),
2, 4 (SHIFT + 2), FREQ, and PERIOD (SHIFT + FREQ).
2. Select the RESOLUTION submenu and press ENTER. If it is not shown on the display, use
the PREV or NEXT keys to locate it.
3. Use the PREV and NEXT keys to find the desired resolution. Press ENTER on your choice.
NOTE The resolution of AC measurements is fixed at 6 1/2 digits.
NOTE The options for frequency and period measurements are 4 1/2 (slow), 5 1/2 (slow), and 6
1/2 (slow).
Figure 4-3
Front panel resolution
How to set the resolution using the remote interface:
Use the following commands on your PC terminal to set the resolution for your measurement:
CONFigure:<function> <range>,<resolution>
MEASure:<function>? <range>,<resolution>
SENSe:<function>:RESolution <resolution>
DC input resistance
Definition
To reduce the effect of loading errors due to the input resistance, the Model 2100 allows you to
select a much larger input resistance (> 10G ) for low input DC voltage (100mV, 1V, and 10V)
FILTER
NEXT
PREV
DIGITS
RATIO
%
MIN/MAX
NULL
ESC
ENTER
AUTO
SINGLE
TRIGGER
STORE
RECALL
LOCAL
SHIFT
CONFIG
MENU
AUT O
DCV
ACV
2
2
FREQ
CONT
TEMP
4 WIRE
RATIO
V
INPUT
PEAK
200V
PEAK
HI
LO
PEAK
500V
3A
RMS
INPUTS
3A 250V
FRONT/REAR
AMPS
R
1000V
REF
CAT 1000V
CAT 600V
LOCK
SETUP
ACV
2
2
FUNCTION
DCI ACI
4
PERIOD
LIMITS MX+B
dB
EXTRIG
HOLD
MATH
TRIGGER MEMORY
dBm
RANGE
DISPLAY
NEXT
PREV
POWER
OFF
ON
SENSE
F
NEXT
PREV
ENTER
DCV
2
FREQ
SHIFT
CONFIG
DIGITS
or

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2100 and is the answer not in the manual?

Keithley 2100 Specifications

General IconGeneral
BrandKeithley
Model2100
CategoryMultimeter
LanguageEnglish

Related product manuals