4-32 Return to Section Topics 2100-900-01 Rev. D / September 2011
Section 4: Front Panel Operations Model 2100 6 1/2-Digit Resolution Digital Multimeter User’s Manual
3. Use the PREV and NEXT keys to select the DISPLAY submenu and press ENTER.
4. Use the PREV and NEXT keys to select either ON or OFF and press ENTER (refer to
Figure 4-28).
Figure 4-28
Controlling the display from the front panel
Controlling the display from a remote interface
To control the instrument display from a remote interface:
Use the following commands to control the instrument display, or to send a message to the
display:
DISPlay {OFF|ON} Turns the display off or on
DISPlay:TEXT <quoted string> Displays the string you type in
DISPlay:TEXT:CLEar Clears the message displayed
Beeper
Definition
The Model 2100 Digital Multimeter beeps when certain conditions are met or when an error
occurs. When you don't want the beeper to sound, you can disable it. Although you can turn off the
beeper, the click sound you hear when a key is pressed will not be disabled. The beeper state is
stored in volatile memory, and the default will be restored when the meter has been turned-off or
after a remote interface reset.
If the beeper is disabled, you will not hear meter beeps when:
A new minimum or maximum is found in Min/Max operation.
A stable reading is detected and held.
The test voltage is within the limits in diode testing.
The source signal fails the limit testing.
If the beeper is disabled, the meter still emits a tone when:
An error occurs.
Any key on the front panel is pressed.
The threshold value is exceeded in continuity testing.
Default beeper setting
The beeper is enabled when it is shipped from the factory.
Controlling the beeper
FILTER
NEXT
PREV
DIGITS
RATIO
%
MIN/MAX
NULL
ESC
ENTER
AUTO
SINGLE
TRIGGER
STORE
RECALL
LOCAL
SHIFT
CONFIG
MENU
AUT O
DCV
ACV
22
FREQ
CONT
TEMP
4 WIRE
RATIO
V
INPUT
PEAK
200V
PEAK
HI
LO
PEAK
500V
3A
RMS
INPUTS
3A 250V
FRONT/REAR
AMPS
R
1000V
REF
CAT 1000V
CAT 600V
LOCK
SETUP
ACV
22
FUNCTION
DCI ACI
4
PERIOD
LIMITS MX+B
dB
EXTRIG
HOLD
MATH
TRIGGER MEMORY
dBm
RANGE
DISPLAY
NEXT
PREV
POWER
OFF
ON
SENSE
F
NEXT
PREV
ENTER
MENU