11. Programming
Coffee Boiler - this parameter includes
the items for setting the coffee boiler
temperature; values that can be set
are 60°C to 110°C (140°F to 230°F)
withstepsof0.5°C.Group temperature
programming with offset correction
possible (see section in pages below).
Softener Reg. - includes the resin
regeneration parameters: litres of resin
(from0.1lto25l),hardness(from0°Fto
45°F).Thedecreasingresinefciency
level is also indicated.
Change water Filter
- On reaching the
litrelevelsetonthedisplayamessageis
displayedwhichpromptsreplacement
ofthelter.
For both functions, an efficiency
percentage is displayed (Softener/
Filter),descendingfrom100%to0%.
Maintenance -includes4submenus
for setting maintenance parameters:
- Max cycles -
the number of cycles
set.
- Max days -
thenumberofdaysset.
- No. cycles/days - this is the
numberofcyclesanddaysuntilnext
maintenance.
- Maintenance - YES/NO.
Enables (YES) or does not enable
countdownofthecyclesanddaysuntil
thenextmaintenanceactivity.
Bds - seesection“BDSActivation”in
the following pages.
Flush -
see section “Enabling Flush
key”inthefollowingpages.
Low Power - YES/NO
Drying Time
-coffeediscdryingtime
from0to5withstepsof0.1seconds.
Screensaver-Possibilityofprogram-
mingthescreensaverdisplaytime(from
30"to20')
Standard data - Allows loading of
standarddataorrecongurationofthe
machine. In both cases the machine is
automaticallyrestarted.
Password- allows change of the code
for accessing technical programming.