Grove Published 3-23-2020, Control # 654-04 4-49
GRT655/655L OPERATOR MANUAL OPERATING PROCEDURES
Status Bar
The following are the icons which can appear in the
Status Bar (3, Figure 4-18 and Figure 4-19) of the
ODM Main Screen:
Item Description Graphic Explanation
42
Swing Disabled
Indicator
Indicates the swing function is disabled (refer to Crane Function
Enable/Disable Switch, page 3-6 and Swing Enable/Disable Switch,
page 3-13).
Swing Standby
Indicator (Amber -
Constant On)
Indicates the swing left or right function is enabled, but is in a
standby mode due to the operator not being seated (causing seat
switch to open).
The swing function is re-enabled by either sitting in the operator seat
or by actuating a dead-man switch on the left or right dual axis
controllers [refer to Deadman Switches (Optional) (Dual Axis
Controllers only), page 3-16].
Swing Standby
Indicator (Amber -
Flashing)
Indicates the swing function is actuated (controller actuated) when
the swing function is changed from disabled to enabled.
Allow controller to return to its neutral position, then re-enable the
swing function.
Swing Enabled
Indicator (Green)
Indicates the swing function is enabled (refer to Crane Function
Enable/Disable Switch, page 3-6 and Swing Enable/Disable Switch,
page 3-13).
43
Telescope Disabled
Indicator
Indicates the telescope function is disabled (refer to Crane Function
Enable/Disable Switch, page 3-6 and Boom Telescope
Enable/Disable Switch, page 3-13).
Telescope Standby
Indicator (Amber -
Constant On)
Indicates the telescope function is enabled, but is in a standby mode
due to the operator not being seated (causing seat switch to open).
The telescope function is re-enabled by either sitting in the operator
seat or by actuating a dead-man switch on the left or right dual axis
controllers [refer to Deadman Switches (Optional) (Dual Axis
Controllers only), page 3-16].
Telescope Standby
Indicator (Amber -
Flashing)
Indicates the telescope extend or retract function is actuated
(controller actuated) when the telescope function is changed from
disabled to enabled.
Allow controller to return to its neutral position, then re-enable the
telescope function.
Telescope Enabled
Indicator (Green)
Indicates the telescope function is enabled (refer to Crane Function
Enable/Disable Switch, page 3-6 and Boom Telescope
Enable/Disable Switch, page 3-13).