LUBRICATION AND MAINTENANCE GRT655/655L OPERATOR MANUAL
6-20 Published 3-23-2020, Control # 654-04
Item
Lube Point
Description
Figure
No.
Approved
Lubricant
Lube Capacity Lube Interval Application
Turntable
40
Turntable
Gearbox
Figure 6-8 H
5.0 L
(5.3 qt)
Check and fill every
50 hours
Drain and fill after
first 250 hours and
every 500 hours or
12 months thereafter.
Fill gearbox to
markings on
dipstick.
41
Turntable Gear
and Drive Pinion
Figure 6-8 G Coat all teeth 500 hours or 6 months Spray on
42
Turntable
Bearing
Figure 6-8 A
Until grease
extrudes from
entire bearing
circumference
500 hours or 6 months
2 grease fittings at
front of turntable.
NOTE: Rotate turntable 90° and apply grease to fittings. Continue rotating in 90° increments and grease fittings until
entire bearing is greased.
FIGURE 6-8
9030-7
41
40
9030-8
40
42