Manitowoc Published 04-06-18, Control # 231-14 4-25
MLC650 VPC-MAXâ„¢ OPERATOR MANUAL SET-UP AND INSTALLATION
Installing the VPC-MAX Beam
See Figure 4-25 for the following procedure.
Perform steps 1
-3 only if the beam is being installed on a
different crane than it was removed from
1. Position the beam up limit switches (1) to the highest
position.
2. Position the beam-on-hook limit switches (2) to the
lowest position.
3. Position the limit switch tripping brackets (3) on the
VPC-MAX
beam assembly (4) to the rearmost position.
4. Remove the two plates and four pendants from the
counterweight tray assembly. See "Handling the
Actuator" on page 4-16.
5. Attach the pendants to the four lifting lugs (5) on the
VPC-MAX
beam assembly.