TM
SAFETY GUIDELINES
If the tool suddenly stalls while cutting wood, release the trigger switch, unplug the
tool and free the blade from the wood. The saw may now be started and the cut
finished.
FUSES may “blow” or circuit breakers may trip frequently if:
a. MOTOR is overloaded – overloading can occur if you feed too rapidly or make
too many start/stops in a short time.
b. LINE VOLTAGE is more than 10% above or below the nameplate voltage
rating. For heavy loads, the voltage at motor terminals must equal the voltage
specified on the nameplate.
c. IMPROPER or dull saw blades are used.
Most motor troubles may be traced to loose or incorrect connections, overload,
low voltage or inadequate power supply wiring. Always check the connections, the
load and supply circuit if the motor doesn’t run well. Check minimum gauge for the
length of cord you are using on the chart below.
GUIDELINES FOR EXTENSION CORDS
Use a proper extension cord. Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one heavy enough to carry the current
your product will draw. An undersized cord will cause a drop in line voltage, resulting
in loss of power and overheating. The table below shows the correct size to use
depending on cord length and nameplate amperage rating. If in doubt, use the next
heavier gauge. The smaller the gauge number, the heavier the cord.
Be sure your extension cord is properly wired and in good condition. Always replace
a damaged extension cord, or have it repaired by a qualified person before using it.
Protect your extension cords from sharp objects, excessive heat and damp or wet
areas.
Use a separate electrical circuit for your tools. This circuit must consist of not less
than a #12 wire with a 20 A time-delayed fuse or a #14 wire with a 15 A time-delayed
fuse. NOTE: When using an extension cord on a circuit with a #14 wire, the extension
cord must not exceed 7.6 m (25’) in length. Before connecting the tool to the power
line, make sure the switch is in the OFF position and the electric current is rated the
same as the current stamped on the motor nameplate, running at a lower voltage will
damage the motor.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MasterCraft MAXIMUM 055-6768-8 and is the answer not in the manual?

MasterCraft MAXIMUM 055-6768-8 Specifications

General IconGeneral
BrandMasterCraft
ModelMAXIMUM 055-6768-8
CategorySaw
LanguageEnglish

Related product manuals