6-107
MOV(P),DMOV(P)
1
2
3
4
4
6
7
8
6.4 Data Transfer Instructions
6.4.1 16-bit and 32-bit data transfers (MOV(P),DMOV(P))
6.4 Data Transfer Instructions
6.4.1 16-bit and 32-bit data transfers (MOV(P),DMOV(P))
MOV(P),DMOV(P)
Function
MOV
(1) Transfers the 16-bit data from the device designated by to the device designated by .
DMOV
(1) Transfers 32-bit data at the device designated by to the device designated by .
Operation Error
(1) There are no operation errors associated with the MOV(P) or DMOV(P) instruction.
: Data to be transferred or the number of the device where the data to be transferred is stored (BIN 16/32 bits)
: Number of the device where the data will be transferred (BIN 16/32 bits)
Setting
Data
Internal Devices
R, ZR
J\
U\G
Zn
Constants
K, H
Other
Bit Word Bit Word
––
–– ––
Basic
Process
High
performance
Redundant
Universal
LCPU
P
Command
Command
MOV, DMOV
MOVP, DMOVP
S
D
S D
indicates an instruction symbol of MOV/DMOV.
S
D
S
D
S
D
b15
1
Before transfer
0 1 1 0 1 0 0 0 1 1 1 0 0 10
b0
b15
1
0
1 1
0
1
0 0 0
1 1 1
0 0
1
0
b0
After transfer
Transfer
S
D
S
D
1
Before transfer
0 1 101 0 0 0 1 110 0 10
b15 b0 b0b15
After transfer
1
0
1 1
0
1
0 0 0
1 11
0 0
1
0
b15 b0 b0b15
+1
+1
S
D
D
S
D
S
Transfer

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC Q Series and is the answer not in the manual?

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC Q Series
CategoryController
LanguageEnglish

Related product manuals