ODU MOUNTING 5-5
Installation NWD-107460-02E
Note The values in the following table are valid for screws and bolts which
have been greased according to the installation instructions.
Torques for RFS
Bolt M5 5 Nm
M6 8 Nm
M8 17 Nm
M10 35 Nm
M12 50 Nm
U-Bolt, V-Bolt (Pipe mount & safety collar) M10 20 Nm
Hexagonal brass nut of fine adjustment (Azimuth, Elevation) M8 5 Nm
M10 10 Nm
M12 17 Nm
Hexagonal socket stainless steel screws
(Feed systems install on aluminium mounting plate)
M3 0.2 Nm
M4 0.4 Nm
Exceptions
Fixing screw of the azimuth fine adjustment spindle M8 x 30 8 Nm
M12 x 55 17 Nm
Special application: NOT greased
Fixing screw of the plastic radome B4.2 3 Nm