Program 16 : Department Group Setup
16-02 : Department Group Assignment for Extensions
Level
IN
Description
Use Program 16-02 : Department Group Assignment for Extensions to set the Department
Groups. The system uses these groups (32 Department Groups) for Department Calling. Assign pilot
numbers to Department Groups you set up in Program 11-07. This lets system users place calls to the
departments. Use Program 16-01 to set the priority of each extension in each Department Group.
When a call comes to the group, the extensions ring in order of their priority.
Input Data
Extension Number Maximum four digits
Item
No.
Group Num-
ber
Priority Default Description Related Program
01 1~32 1~999 1-xxx
(See Note)
Set up the Department Group
called by the pilot number and
the extension priority when a
group is called. Call Pickup
Groups are set up in 23-02.
11-07
16-01
The initial value of a priority becomes the ports numerical order assigned in Programs 11-02 and 11-04. (Ex-
tension ports are 1 ~ 128 Virtual extension ports are 1 ~ 50.)
Conditions
None
Feature Cross Reference
• Department Calling
ISSUE 1.1 SL1000
Program
16