Program 34 : Tie Line Setup
34-07 : E&M Tie Line Timer
Level
IN
Description
Use Program 34-07 : E&M Tie Line Timer to define the system service tone timers.
Input Data
Item No. Item Input Data Default
01 First Digit Pause (E&M Immediate Start) 0 ~ 64800 seconds 3 seconds
02 First Digit Pause (E&M Wink Start) 0 ~ 64800 seconds 0
03 First Digit Pause (LD Trunk) 0 ~ 64800 seconds 3 seconds
04 LD Trunk Guard Time 0 ~ 64800 seconds 0
05 Trunk Answer Detect Timer for E&M 0 ~ 64800 seconds 30 seconds
Conditions
• If Program 34-07-05 is left at default (30) the transferred call recalls to the station that performed
the transfer when not answered.