Program 10 : System Configuration Setup
10-28 : SIP System Information Setup
Level
SA
Description
Use Program 10-28 : SIP System Information Setup to set up basic SIP trunking.
Input Data
Item No. Item Input Data Default
01 Domain Name
Set the domain name of the SIP-URL.
Up to 64 Characters
(ex. : UserID@HostName.DomainName)
None
02 Host Name
Set the host name of the SIP-URL.
Up to 48 Characters
(ex. : UserID@HostName.DomainName)
None
03 Transport Protocol
Set the protocol for the connection.
0 = UDP
1 = TCP
0
04 UserID
User ID in the SIP Invite Setup message. Use it for
outbound caller ID information if no information is
assigned in commands 21-17, 21-19, 15-16, 14-12
and 10-36. A call cannot be completed across the
span if there is no outbound CID info. The reason
for this is: the from and display portion of the invite
message would be blank, and it would not know
where the call originated from.
Up to 32 Characters
When assigning the User ID, the ID may
contain only alpha characters. (A space
and/or special characters are not al-
lowed in the User ID field).
(ex. : UserID@HostName.DomainName)
None
05 Domain Assignment
If the information from Telco was a domain name
(siptrunk@sip.com) then set to domain. If the infor-
mation for Telco was a IP address then set to IP
Address.
0 = IP Address
1 = Domain Name
0
06 IP Trunk Port Binding
Trunk port binding is only used for SIP trunks to
the provider in Non-Registration Mode only. When
this is disabled, an inbound call comes in and fol-
lows your DID routing but it comes in on the first
available trunk. When enabled, the inbound call
comes in and follows your normal DID routing but
maps to that specified trunk. If that trunk is busy, it
sends back a busy unless you build a hunt group.
To build the hunt group, it references command
14-12-02 (pilot register ID). This then points you to
command 10-36-02. All the numbers with the
same pilot are in the same hunt group.
0=Disable
1 = Enable
0
Conditions
None
Feature Cross Reference
None
ISSUE 1.1SL1000
Program
10
Program 10 : System Configuration Setup2-32

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC SL100 and is the answer not in the manual?

NEC SL100 Specifications

General IconGeneral
BrandNEC
ModelSL100
CategoryTelephone
LanguageEnglish

Related product manuals