Program 15 : Extension, Basic Setup
15-05 : IP Telephone Terminal Basic Data Setup
Level
IN
Description
Use Program 15-05 : IP Telephone Terminal Basic Data Setup to set up the basic settings for an IP
telephone.
Input Data
Extension Number Maximum four digits
Item
No.
Item Input Data Default Description
Related
Program
Note
01 Terminal Type 0 = NGT
1=H.323
2=SIP
3 = MEGACO
4 = SIP-MLT
-
02 IP Phone Fixed
Port Assign-
ment
MAC address
00-00-00-00-00-00 ~
FF-FF-FF-FF-FF-FF
00-00-00-
00-00-00
MAC Address of reg-
istered SIP MLT
phone is stored
and/or can input the
MAC address of an
SIP MLT phone so
when it comes on-
line it is provided
with the extension in
which the MAC ad-
dress matches.
15-05-01
04 Nickname Up to 48 characters No setting Nickname section on
Invite message.
Example :
Extension 100 has a
Nickname set to
PAUL.
Extension 101 has
command 15-05-17
set to Nickname.
The inbound call to
extension 101, from
100, shows PAUL.
15-05-17
07 Using IP
Address
0.0.0.0 ~
255.255.255.255
- 15-05-01
09 Call procedure
port
0 ~ 65535 - 15-05-01
15 CODEC Type 1 = Type 1
2 = Type 2
3 = Type 3
4 = Type 4
5 = Type 5
1 Assign the CODEC
Type of the SIP MLT.
84-24
84-11
15-05-01
16 Authentication
Password
Up to 24 characters None Assign the authenti-
cation password for
SIP single line tele-
phones.
15-05-01
ISSUE 1.1 SL1000
Program
15