EasyManuals Logo
Home>NEC>Telephone>SL100

NEC SL100 User Manual

NEC SL100
598 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
Program 10 : System Configuration Setup
10-23 : SIP System Interconnection Setup
Level
SA
Description
Use Program 10-23 : SIP System Interconnection Setup to determine if the system is intercon-
nected and define the IP address of another system, call control port number and alias address for
SL1000 system interconnection.
Input Data
System Number 001 ~ 1000
Item No. Item Input Data Default
01 System
Interconnection
0 = No (Disable)
1 = Yes (Enable)
0
02 IP Address 0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
0.0.0.0
03 Call Control Port 1 ~ 65535 1720
04 Dial Number Up to 12 digits (0 ~ 9) Not Set
Conditions
None
Feature Cross Reference
None
ISSUE 1.1SL1000
Program
10
Program 10 : System Configuration Setup2-28

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC SL100 and is the answer not in the manual?

NEC SL100 Specifications

General IconGeneral
BrandNEC
ModelSL100
CategoryTelephone
LanguageEnglish

Related product manuals