Program 81 : Basic Hardware Setup for Trunk
81-08 : T1 Trunk Timer Setup
Level
IN
Description
Use Program 81-08 : T1 Trunk Timer Setup to define the basic timer setting of each T1 Trunk type.
Input Data
Item Name Input Data Default
01 Answer Signal Detection Time (Loop) 1 ~ 250 (4 ms ~ 1000 ms) 15 (60 ms)
02 Answer Signal Detection Time (Ground) 1 ~ 250 (4 ms ~ 1000 ms) 15 (60 ms)
03 Answer Signal Detection Time (DID) 1 ~ 250 (4 ms ~ 1000 ms) 15 (60 ms)
04 Answer Signal Detection Time (E&M) 1 ~ 250 (4 ms ~ 1000 ms) 15 (60 ms)
05 Answer Signal Detection Time (OPX) 1 ~ 250 (4 ms ~ 1000 ms) 15 (60 ms)
06 Clear Signal Detection Time (Loop) 1 ~ 255 (100 ms ~ 25500 ms) 6 (600 ms)
07 Clear Signal Detection Time (Ground) 1 ~ 255 (100 ms ~ 25500 ms) 6 (600 ms)
08 Clear Signal Detection Time (DID) 1 ~ 255 (100 ms ~ 25500 ms) 6 (600 ms)
09 Answer Signal Detection Time (E&M) 1 ~ 255 (100 ms ~ 25500 ms) 6 (600 ms)
10 Clear Signal Detection Time (OPX) 1 ~ 255 (100 ms ~ 25500 ms) 6 (600 ms)
11 Ringing Signal Detection Time (Loop) 1 ~ 250 (8 ms ~ 2000 ms) 10 (80 ms)
12 Ringing Signal Detection Time (Ground) 1 ~ 250 (8 ms ~ 2000 ms) 10 (80 ms)
13 Ringing Signal Detection Time (DID) 1 ~ 250 (8 ms ~ 2000 ms) 10 (80 ms)
14 Ringing Signal Detection Time (E&M) 1 ~ 250 (8 ms ~ 2000 ms) 10 (80 ms)
15 Ringing Signal Detection Time (OPX) 1 ~ 250 (8 ms ~ 2000 ms) 10 (80 ms)
16 Ringing Signal Stop Detection Time (Loop) 1 ~ 255 (100 ms ~ 25500 ms) 50 (5000 ms)
17 Ringing Signal Stop Detection Time
(Ground)
1 ~ 255 (100 ms ~ 25500 ms) 50 (5000 ms)
18 Ringing Signal Stop Detection Time (DID) 1 ~ 255 (100 ms ~ 25500 ms) 50 (5000 ms)
19 Ringing Signal Stop Detection Time (E&M) 1 ~ 255 (100 ms ~ 25500 ms) 50 (5000 ms)
20 Ringing Signal Stop Detection Time (OPX) 1 ~ 255 (100 ms ~ 25500 ms) 50 (5000 ms)
21 Loop Current Detection Time (Loop) 1 ~ 250 (4 ms ~ 1000 ms) 40 (160 ms)
22 Loop Current Detection Time (Ground) 1 ~ 250 (4 ms ~ 1000 ms) 40 (160 ms)
23 Loop Current Detection Time (DID) 1 ~ 250 (4 ms ~ 1000 ms) 40 (160 ms)
24 Loop Current Detection Time (E&M) 1 ~ 250 (4 ms ~ 1000 ms) 40 (160 ms)
25 Loop Current Detection Time (OPX) 1 ~ 250 (4 ms ~ 1000 ms) 40 (160 ms)
26 DP Break Send Time (ALL) 1 ~ 250 (4 ms ~ 1000 ms) 15 (60 ms)
27 DP Make Send Time (ALL) 1 ~ 250 (4 ms ~ 1000 ms) 10 (40 ms)
28 DP InterDigit Send Time (ALL) 1 ~ 255 (100 ms ~ 25500 ms) 7 (700 ms)
29 HookFlash Send Time (Loop) 1 ~ 255 (100 ms ~ 25500 ms) 5 (500 ms)
30 HookFlash Send Time (Ground) 1 ~ 255 (100 ms ~ 25500 ms) 5 (500 ms)
31 HookFlash Send Time (DID) 1 ~ 255 (100 ms ~ 25500 ms) 5 (500 ms)
ISSUE 1.1 SL1000
Program
81
Programming Manual 2-433