Mercury 310 Automated Gate System
Installation and Programming Manual
3737
Two seconds (2s) after limits are learned in the Mercury 310 controller, the controller automatically enters
Satndby Mode. Standby Mode puts the board into a “low power mode” when it’s not in use. This is a signicant
power saving feature for solar panel applications.
The controller also enters Standby Mode during normal operation after two minutes of controller inactivity or
fteen seconds after an actuator motor stops running after a gate operation.
When the controller is in Standby Mode:
’ A red "heartbeat" decimal point will ash every two seconds in the lower right of the display to indicate the
controller is on and in Standby Mode.
’ Any active LEDs and 12V switched outputs are turned o.
’ Pressing any button will “wake” the board and disable Standby Mode.
Standby Mode is disabled:
’ for two minutes if the rotary switch position is changed or any on-board buttons are pressed.
’ during a rmware update or if debug data is being captured.
’ if there is an active error or event preventing normal operation.
8.2 STANDBY MODE
Mercury 310
www.ApolloGateOpeners.com | (800) 878-7829 | Sales@ApolloGateOpeners.com