AFP-2800 - Fire Indicator Panel – Panel Operation Page 39
©
N
OTIFIER
I
NERTIA
P
TY
L
TD
,
2001
WWW
.
INERTIA
.
COM
.
AU
4
44
4
4
44
4
.
..
.
.
..
.
3
33
3
3
33
3
.
..
.
.
..
.
4
44
4
4
44
4
S
SS
S
S
SS
S
E
EE
E
E
EE
E
R
RR
R
R
RR
R
V
VV
V
V
VV
V
I
II
I
I
II
I
C
CC
C
C
CC
C
E
EE
E
E
EE
E
M
MM
M
M
MM
M
E
EE
E
E
EE
E
N
NN
N
N
NN
N
U
UU
U
U
UU
U
-
--
-
-
--
-
I
II
I
I
II
I
S
SS
S
S
SS
S
O
OO
O
O
OO
O
L
LL
L
L
LL
L
A
AA
A
A
AA
A
T
TT
T
T
TT
T
E
EE
E
E
EE
E
This screen provides the ability to isolate or de-isolate any point on the system. Isolating an input will prevent it
causing an alarm and isolating an output will prevent the output from activating. Note that an isolated point is seen
as inactive by the panel and hence, in a logic programming script, it will return the value FALSE (or TRUE if the
NOT function is applied to it within the script).
1)
AZF LIST
2)
DOUT LIST
3)
DIN LIST
4)
ZONE LIST
5)
FLASHSCAN LIST
6)
RANGE (FLASHSCAN)
28 JAN 1999 14:44:37
SELECTDOWNUP MENU
ISOLATE / DE-ISOLATE A POINT
01 OCT 1999 14:44:37
SELECT FROM LIST
A = 0
F = 0
I = 0
N = 1
Actions:
• Use the UP
and DOWN buttons to scroll through options and then use the SELECT button to select the
highlighted option
(or button 1
to 6 from numeric keypad)
• Press MENU
to return to the Service Menu screen.
Selection Action required
1
Will display the AZF list as per page 35 with an ISOL
and a DEISOL soft button. Use the UP and
DOWN
buttons to select the appropriate point and press the appropriate function. If the point is
isolated, an “I” will appear on the right hand side of the screen next to the point.
2
Will display the Dout list as per page 36 with an ISOL
and a DEISOL soft button. Use the UP and
DOWN
buttons to select the appropriate point and press the appropriate function. If the point is
isolated, an “I” will appear on the right hand side of the screen next to the point.
3
Will display the Din list as per page 37 with an ISOL
and a DEISOL soft button. Use the UP and
DOWN
buttons to select the appropriate point and press the appropriate function. If the point is
isolated, an “I” will appear on the right hand side of the screen next to the point.
4
Will display the Zones list as per page 24 with an ISOL
and a DEISOL soft button. Use the UP and
DOWN
buttons to select the appropriate zone and press the appropriate function. Isolating or de-
isolating in this screen will isolate/de-isolate ALL points within the display zone.
5
Will display the FlashScan list as per page 25 with an ISOL
and a DEISOL soft button. Use the
UP
and DOWN buttons to select the appropriate FlashScan point and press the appropriate
function.
6
Will prompt for the first FlashScan point and the last FlashScan point.
Pressing the ISOL
and DEISOL soft buttons will isolate/de-isolate the selected range of FlashScan
points.