5-12
OPERATION
Protect level
5-9 Key Protect Setting
Key protect includes "operation/adjustment lockouts", "setting level lockout", "setting
change lockout", and "forced-zero lockout", and allows restrictions on moving among
levels and various setting changes.
This types of key protect restrict the key operation at the operation and adjustment
levels.
This type of key protect restricts moving to "initial setting level" and "advanced-
function setting level".
This type of key protect restricts the key operation for setting change.
It prohibits the product from entering the changing state, except that the following
operation is allowed.
- Changes in set values of all parameters at the protect level
- Move to the advanced-function level
This type of key operation restricts the key operation that activates or deactivates the
forced-zero function.
For the factory set values, refer to the "Parameter List" at the end of this document.
Parameter Set value
Operation level
Move to
adjustment level
Current value
display
OUT set value
display
oapt
(OAPT)
0 Enable Enable Enable
1 Enable Enable
Disable
2 Enable
Disable Disable
Parameter Set value
Move to initial
setting level
Move to
advanced-function
setting level
icpt
(ICPT)
0 Enable Enable
1 Enable
Disable
2
Disable Disable
Parameter Set value
Key operation for
setting changes
wtpt
(WTPT)
off Enable
on
Disable
Parameter Set value
Key operation for
activating or deactivating
the forced-zero function
zrpt
(ZRPT)
off Enable
on
Disable
Operation/
Adjustment
Lockouts
Setting Level
Lockout
Setting Change
Lockout
Forced-zero
Lockout
(Only K3MA-J)
CHAPTER 5 OPERATION