5-34
OPERATION
Advanced-function setting level
CHAPTER 5 OPERATION
If the display auto-return
function is activated in the
middle of parameter setting,
the product saves the current
value of the parameter and
then returns to the current
value display mode.
5-24 Changing the Display
Auto-return Time
This parameter allows you to change the display auto-return time.
If no key is operated for a prescribed time, the product returns to the current value
display mode at the operation/adjustment level. This prescribed time is called the
display auto-return time.
Procedure
A. When the product is at the operation level, press
the L key and hold it down for at least three
seconds to enter the initial setting level.
•"
5
" will appear on the level indicator, indicating
the product has entered the initial setting level.
B. Enter password "K3MA-J or K3MA-F : -0169,
K3MA-L : -169" in parameter "amov" to enter
the advanced-function setting level. For details
on how to move to the advanced-function setting
level, refer to "5-2 Moving among Levels".
•"f" will appear on the level indicator, indicating
the product has entered the advanced-function
setting level.
C. Press the M key several times until parameter
"
ret" appears on the main indicator.
D. Press the S key to display the set value of the
parameter on the main indicator.
The current set value of the display auto-return
time will appear on the main indicator.
E. Press the S key again.
The set value will start blinking, indicating the
product is in the change state.
F. Use the S and U keys to change the set value.
G. Press the M key to go to the next parameter.
The change is saved.
H. Press the L key and hold it down for at least
one second to return to the initial setting level.
I. Press the L key and hold it down for at least
one second to return to the operation level.
Parameter Set value
Description
ret
(RET)
0
0 sec: Display auto-return is not available.
1-99 1 to 99 sec: Display auto-return time

Table of Contents

Other manuals for Omron K3MA-J

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron K3MA-J and is the answer not in the manual?

Omron K3MA-J Specifications

General IconGeneral
BrandOmron
ModelK3MA-J
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals