EasyManuals Logo
Home>Omron>Measuring Instruments>K3MA-J

Omron K3MA-J User Manual

Omron K3MA-J
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
V
Observe the following precautions to ensure safety.
(1) Maintain the power supply voltage within specifications.
(2) Use the product within the rated load.
(3) Be sure to check each terminal for correct number and polarity before connection.
Incorrect or reverse connection may damage or burn out internal components of the product.
(4) Be sure to tighten the terminal screws.
Recommended tightening torque: 0.43-0.58 N·m
Loose screws may result in product failure or malfunction.
(5) Do not connect anything to unused terminals.
(6) Install a switch or a circuit breaker so that the operator can turn off the power supply without delay
and attach an appropriate label.
(7) Do not disassemble, repair, or modify the product.
(8) Do not use the product in flammable or explosive atmosphere.
(9) For the wiring, use wires that can withstand a temperature of 70°C or higher.
(10) For the crimp terminals for crimp terminal wiring connections, use the specified size (M3, width of
5.8 m or less). For wiring for bare-wire connections, use AWG22 to AWG14 for the power supply,
and AWG28 to 16 for other than the power supply. (Wire jacket strip length: 6 to 8 mm)
(11)Let the product warm up at least 15 minutes after turning on the power.
For proper usage of the product:
(1) Do not use the product in such an environment that is subject to the following:
Direct heat radiation from any heat source
Water flooding or oil splashes
Direct sunlight
Dust or corrosive gases (especially, sulfuric or ammonia gas)
Rapid temperature changes
Condensation or icing due to high humidity
Strong vibration or mechanical shock
(2) Do not block heat dissipation from the product, i.e., allow sufficient space for heat dissipation.
(3) Be sure that the rated voltage is reached within 2 seconds after the power is turned ON.
(4) Conduct aging for at least 15 minutes after turning ON the power for correct measurement.
(For K3MA-L: 30 minutes)
(5) To prevent the effect of static electricity, do not touch live terminals or slit areas of the product.
(6) Do not apply heavy load to the product. Doing so may deform or deteriorate the product.
(7) Do not use paint thinner for cleaning. Use commercially available alcohol.
Installation and connection
(1) Mount the product to a panel that is 1 to 8 mm thick.
(2) Install the product in a horizontal position.
(3) Use crimp-style terminals fit for the screw size.
NOTICE

Table of Contents

Other manuals for Omron K3MA-J

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron K3MA-J and is the answer not in the manual?

Omron K3MA-J Specifications

General IconGeneral
BrandOmron
ModelK3MA-J
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals