3-2 Quick Reference
50
Item Procedure See
Ladder
Monitor
To display execution
status on the ladder
diagram.
To display the present
values of words used in
instructions.
Start the Ladder Monitor in the ladder
monitoring state.
Page 67
To change the display
format of word present
values.
Pressing the
Dec/Hex
Button switches to
hexadecimal, decimal, and signed decimal
in order.
Page 68
Multiple I/O
Monitor
To monitor the present
values of the specified I/O
memory addresses.
1. Press the
I/O Mon
Button.
2. Press the
Add
Button.
3. Specify Bit or Word.
4. Specify the addresses.
Page 69
Force Set/
Reset
To force-set/reset or
set/reset a selected bit.
1. Select the bit from the ladder display
area or the Multiple I/O Monitor.
2. Press the
Change
Button.
3. Select either
Force Set/Reset
or
Set/Reset
.
4. Press the
Update
Button.
Page 71
Changing
present
value
To change the present
value of a selected word.
1. Select the word from the ladder display
area or the Multiple I/O Monitor.
2. Press the
Change
Button.
3. Set the present value.
4. Press the
Update
Button.
Page 74
Changing
timer/
counter set
value
To change the set value of
a selected timer or
counter.
1. Select the second operand (set value) of
a timer/counter instruction from the
ladder display area.
2. Press the
Change
Button.
3. Input the set value.
4. Press the
Set
Button.
Page 76
Changing
mode
To change the PLC’s
operating mode.
1.
Menu
Button –
Operating Mode
.
2. Select Program, Monitor, or Run.
Page 79
To display current error.
Menu
Button –
PLC Error
Page 80 Displaying
errors
To cancel the error.
Press either the
Clear All Err
or
Clear Err
Button.
Page 81
Monitor
screen
hard copy
To capture the monitor
screen and save it to a
Memory Card as a bmp
file.
Menu
Button – Monitor Hard Copy
Page 82
Change
host
To select PLC for
monitoring by the Ladder
Monitor.
1.
Menu
Button –
Change Host
.
2. Select the host name.
3. Press the
OK
Button.
Page 88
Password
verification
To allow only authorized
operators to perform the
following operations:
Force-setting/resetting
bits
Changing present
values and set values
Changing operating
modes
Starting the
Programming Console
function
1. For the NS15, press function key F1 and
the upper right of the PT screen at the
same time.
For the NS12, NS10, or NS8, press the
upper two corners of the PT screen at the
same time.
2. Select the Use Option.
3. Select the required password level.
4. Press the
Set
Button.
Page 89

Table of Contents

Other manuals for Omron ns series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron ns series and is the answer not in the manual?

Omron ns series Specifications

General IconGeneral
BrandOmron
Modelns series
CategoryTouch terminals
LanguageEnglish

Related product manuals