94
Chapter4
OS32C
User’s Manual
Installation
Example of safety distance calculation for 30mm resolution
K = 1600 mm/s approach speed constant
T = t
1+t2 = 0.58s Overall response time
t
1 = 0.08 seconds OS32C response time (adjustable)
t
2 = 0.5 seconds Max. time required to full stop of the machine
C = 8(30-14 mm)
S = K x T + C = 1600 x 0.58 + 128 = 1056 mm
If the calculated value is more than 500mm, use it for your application installation. The minimum value
of S should not be less than 500mm.