x
Introduction
OS32C
User’s Manual
Make sure to follow all the safety precautions that are necessary to ensure safe use of the product.
• Thoroughly read this installation manual and understand the installation, operation checks, and maintenance
procedures before using the product.
• Loads must satisfy both of the following conditions:
-Not short-circuited
-Not used with a current that is higher than the OSSD rating (250 mA sourcing)
• The main unit must be properly mounted with the proper mounting hardware.
• Do not drop the product, serious damage will occur.
• Comply with all the laws, regulations, and standards of the country/region where the product is used.
• Dispose of the product in accordance with the relevant rules and regulations of the country/region where the
product is used.
Observe the precautions described below to prevent operation failure, malfunctions, or undesirable effects on
product performance.
Installation environment
Do not install the OS32C in the following types of environments:
•Areas where OS32C may be exposed to intense interference light, such as direct sunlight
•Areas with high humidity where condensation is likely to occur
•Areas subject to condensation resulting from severe changes in temperature
•Areas where corrosive gases are present
•Areas exposed to vibration or shock levels higher than in the specification provisions
•Areas where the product may come into contact with water
•Areas where the product may get wet with oil
•Areas where smoke and/or water vapor exists on the laser scanning plane
•Keep the OS32C far enough from devices that generate high frequency noise or eliminate the
noise.
•Be sure to route the OS32C cable separate from high-potential power lines or route through an
exclusive conduit.
This is a class A product. In residential areas it may cause radio interference, in which case the
Responsible Person may be required to take adequate measures to reduce interference.
Wiring and installation
•Make sure to perform wiring while the power supply is OFF. Otherwise, the OS32C may fail to operate
due to the diagnostics function.
•Properly perform the wiring after confirming the signal names of all the terminals.
•Do not operate the control system until 14 seconds or more after turning ON the power of the OS32C.
•Be sure to route the OS32C cable separate from high-potential power lines or through an exclusive
conduit.
•When using a commercially available switching regulator power supply, make sure to ground the FG
terminal (frame ground terminal).
Precautions for Safe Use
Precautions for Correct Use