Warning Zone When an object enters the warning zone, warning zone infringed will be reported. This zone allows
for a larger scanning area than the safety zone and can be used to activate a warning function. This
zone is a non-safety-critical property.
Window Contamination Warning This output can be assigned to the warning output and will turn ON when contamination of the scan
window reaches a certain level.
Window Calibration This is required for replacement of the window.
Window calibration resets the threshold value of window transmittance.
This threshold value is used for Window contamination warning.
Zone Set Select Up to 70 zone sets can be switched according to the wiring for zone set selection. Refer to "Zone Set
Selection" on page 19.
Term Definition

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron OS32C Series and is the answer not in the manual?

Omron OS32C Series Specifications

General IconGeneral
Response Time80 ms
TypeSafety Laser Scanner
Protection StructureIP65
Safety CategoryType 3
Power Supply24 VDC
InterfaceEthernet/IP, PROFINET
Operating Temperature-10°C to 50°C
OutputOSSD
CommunicationEthernet/IP
ConfigurationVia software
Warning ZoneConfigurable