EasyManuals Logo
Home>Omron>Servo Drives>R88D-KN20F-ECT-R

Omron R88D-KN20F-ECT-R User Manual

Omron R88D-KN20F-ECT-R
484 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
3-11
3-1 Servo Drive Specifications
OMNUC G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
3
Specifications
R88D-KN30F-ECT-R/R88D-KN50F-ECT-R
Main Circuit Terminal Block Specifications (TB1)
Main Circuit Terminal Block Specifications (TB2)
Precautions for Correct Use
 Tighten the terminal block screws to the torque of 0.75 N•m (M4) or 1.5 N•m (M5).
 If the torque for terminal block screws exceeds 1.2 N•m (M4) or 2.0 N•m (M5), the terminal block
may be damaged.
 Tighten the fixing screw of the terminal block cover to the torque of 0.2 N•m (M3).
 Tighten the ground screws to the torque of 0.7 to 0.8 N•m (M4) or 1.4 to 1.6 N•m (M5).
Symbol Name Function
24 V Control circuit power
supply input
24 VDC ± 15%
0 V
Symbol Name Function
L1 Main circuit power supply
input
R88D-KN@F-ECT-R (3 to 5 kW):
3-phase 380 to 480 VAC (323 to 528 V) 50/60 Hz
L2
L3
B1 External Regeneration
Resistor connection
terminals
Normally B2 and B3 are connected.
If there is high regenerative energy, remove the short-circuit bar
between B2 and B3 and connect an External Regeneration
Resistor between B1 and B2.
B2
B3
NC Do not connect.
U Motor connection
terminals
Phase U These are the output terminals to the Servomotor.
Be sure to wire them correctly.
V Phase V
W Phase W

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-KN20F-ECT-R and is the answer not in the manual?

Omron R88D-KN20F-ECT-R Specifications

General IconGeneral
BrandOmron
ModelR88D-KN20F-ECT-R
CategoryServo Drives
LanguageEnglish

Related product manuals