10-8
10-3 Trial Operation
OMNUC G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
10
Operation
Test Operation via USB Communications from the CX-Drive
1. Use the Connector CN1.
2. Supply 12 to 24 VDC to the control signal connector pins +24 VIN and COM.
3. Turn ON the Servo Drive power.
4. Connect a USB cable to the USB connector (CN7).
5. Start the CX-Drive and go online with the Servo Drive via USB communications.
6. Select Test Run from the Tuning Menu of the CX-Drive.
7. Select Servo ON to servo-lock the Servomotor.
8. Select Forward or Reverse and start the Servomotor.
The Servomotor will rotate until Stop is selected.
Precautions for Correct Use
The test operation function via USB communications from the CX-Drive cannot be used while
EtherCAT communications are established.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-KN20F-ECT-R and is the answer not in the manual?

Omron R88D-KN20F-ECT-R Specifications

General IconGeneral
BrandOmron
ModelR88D-KN20F-ECT-R
CategoryServo Drives
LanguageEnglish